OCT Anatomy
OCT Imaging
COT Clinical
Optics and Refraction
Fields and Glaucoma
100

Which retinal layer contains the photoreceptor inner and outer segments?

The photoreceptor layer (including the ellipsoid zone).

100

What does OCT stand for?

Optical Coherence Tomography.

100

Which instrument is commonly used to measure intraocular pressure by flattening the cornea?

Goldmann applanation tonometer.

100

What is the unit used to measure refractive power?

Diopter

100

What does IOP stand for?

Intraocular pressure

200

What is the foveal pit, and why does it appear as a depression on OCT?

The central macular depression caused by displacement of inner retinal layers.

200

What is a B-scan in OCT?

A cross-sectional image composed of multiple A-scans.

200

What is the purpose of the swinging flashlight test?

To detect a relative afferent pupillary defect (RAPD).

200

Which lens corrects simple myopia?

A minus (concave/diverging) lens.

200

What does "md" represent on an automated visual field report?

Mean Deviation

300

Which retinal layer contains ganglion cell axons?

Retinal nerve fiber layer (RNFL).

300

Name two common causes of OCT image artifacts.

Examples: eye motion, blinking, poor fixation, segmentation errors, or media opacity.

300

Which cover test detects a tropia, and which detects a phoria?

Cover-uncover detects tropia; alternate cover breaks fusion and reveals total deviation including phoria.


300

What is the spherical equivalent of +2.00 −1.00 × 180?

+1.50 D.

300

What is the difference between fixation losses and false-positive responses in perimetry?

Fixation losses suggest reduced fixation reliability; false positives occur when the patient responds without a valid stimulus.


Both affect confidence in test interpretation.

400

Which highly reflective OCT band is associated with the retinal pigment epithelium?

The RPE/Bruch's membrane complex.

400

How does spectral-domain OCT differ from swept-source OCT?

Spectral-domain uses a broadband light source and spectrometer; swept-source uses a rapidly tunable wavelength laser and a detector.

400

What is the appropriate action when Goldmann mires are irregular and distorted?

Check for tear-film irregularity, staining adequacy and technique; repeat the measurement after correcting the issue.


Distorted semicircles can make the endpoint unreliable.

400

Transpose −2.00 +1.50 × 090 into minus-cylinder notation.

−0.50 −1.50 × 180.

400

What classic visual field defect respects the horizontal meridian and is associated with glaucoma?

A nasal step (or arcuate defect).

500

What is the distinction between intraretinal and subretinal fluid on OCT?

Intraretinal fluid accumulates within retinal layers; subretinal fluid accumulates between the neurosensory retina and RPE.

500

What is a segmentation error, and how can it affect RNFL or macular thickness measurements?

Incorrect automated identification of anatomical boundaries, resulting in inaccurate thickness values.

500

In retinoscopy, what does neutralization mean?

The reflex shows no apparent directional movement when the correct lens power is introduced at the working distance.


Subtract working-distance dioptric power to determine distance refractive error.

500

A spectacle prescription is −3.00 −2.00 × 180. What is the power in the 90-degree meridian?

−5.00 D.

500

How would you interpret progressive RNFL thinning accompanied by repeatable corresponding visual field loss?

As concerning for glaucomatous structural and functional progression, after confirming test quality and clinical correlation.


Review OCT segmentation, signal quality, field reliability and longitudinal trends.