At a confined space, when is entry classified as an entry?
As soon as any part of your body breaking the plane of the opening to the confined space.
What first should be completed
Shut the system down
What must be complete before entry?
A confined space permit must be fully completed with plant manager signature. All items on the confined space regarding mitigation or elimination of hazard completed.
Is lock out tag out required when checking a choke elevator leg?
Yes... Absolutely
What are the three methods of rescue?
Self rescue
None entry rescue
Entry rescue
Risk of fire doesn't happen with choked elevator leg?
Risk of fire could occur with a choked elevator leg due to various reasons.
Daily Double: What are the four positions in a confined space entry and what does each position do?
Attendant
Entrant
Entry Supervisor
Rescue
If you have to reset the bucket once and it goes out again, can you reset the elevator leg again?
No. Get maintenance involved.
If after a confined space has been entered and a hazard that was unaccounted found, what shall occur?
All entrants must immediately exit and reassessment be completed for mitigation /elimination process before going back in. Another permit may need to be filled out to account for the new hazard.
What would the process be if mixer leg shows it is plugged.
Check the routing devices. Tap on the pipes
If those are clear. Lock out the mixer surge conveyor and mixing leg.
Completed a non-permit required confined space document to show air is good and communicate with team member you are going into the pit.
Open the boot to check and see if anything is lodged.