Cable must be fastened or clipped every __ to __ inches if routed horizontally.
18, 24
Interior cable routes must maintain a minimum distance of ___ inches from any electrical wiring.
2
The bonding conductor for bonding Series-6 drop cable must be #___ AWG or larger, insulated solid copper wire.
12
The drop must be bonded directly to the main grounding electrode (i.e., ground rod) for the electrical service
Bonding Option 3
All aerial drops shorter than 150 feet long must be ran with what type of cable
RG 6
Cable must be fastened or clipped every __ to __ inches if routed vertically
30, 36
Cable route through a basement must be routed parallel or perpendicular to the floor joists, NEVER______.
diagonally
The bonding conductor for bonding Series-11 cable must be #__ AWG or larger, insulated solid copper wire.
10
The CATV bond block must be bonded to a #6 AWG solid copper conductor or stub bonded to the property power grounding electrode, if one has been made available on the outside of the property.
Bonding Option 2
Drops using series-11 cable or QR-320 cable shall not exceed ___ feet in length.
300
All exterior entry holes must be drilled so that the outside of the hole is slightly lower than the hole on the inside of the wall to avoid what?
Water Damage
If running cable parallel to the joists, the cable must be attached to the?
side of the joist
The length of the bonding conductor must be as short as practicable and must not exceed ___ ft. in length
20
The drop may be bonded to the metallic meter cabinet using an appropriate and approved clamp
Bonding Option 4
_______ clamps must NEVER be placed over the lashing wire.
Span
Drilling should be from where for wood or vinyl siding?
inside out
Cable MUST ALWAYS enter the premise from below the level of the outside entry hole to prevent?
Moisture from traveling down the cable and into the premise.
Two ___________ must be placed on all bonding conductors (ground wire).
Do Not Remove tags
The drop may be bonded to the grounded interior metal cold water piping system using an appropriate and approved pipe ground clamp
Bonding Option 6
Drop clearance over roads, streets, alleys; nonresidential driveways; parking lots and other areas subject to truck traffic.
18 feet
Drilling should be from where for metal, slate, stucco, hard asphalt, or brick?
outside in
This must be formed below all outside entry holes anywhere cable enters the premise
A minimum diameter drip loop
The resistance between the bond block and the property power grounding electrode must be less than ___ Ohms.
25
The drop must be bonded to the property’s bonding block if a #6 AWG solid copper stub bonded to the property’s bonding bridge
Bonding Option 1
Drop clearance above sidewalks or other pedestrian traffic areas
10 feet