Review Questions
Review Questions
Review Questions
Oxyfuel IQ
Oxyfuel IQ
100

To prevent fume hazard there must be at least _______ cubic feet of air for each welder. 

10,000

100

Cutting operations should never be performed without a ________ in the area. 

Fire watch

100

A good safety practice is

Writing HOT on hot metal

100

In the top and bottom of the acetylene cylinder are safety plugs with a melting point of _________. 

220 f

100

When preparing oxyfuel equipment for use, momentarily crack open the valve on each cylinder to __________.

remove any dirt

200

The smallest standard oxygen cylinder holds about ________ cubic feet of oxygen

85

200

Acetylene gas must be withdrawn from a cylinder at an hourly rate that does not exceed _________ percent of the cylinder capacity. 

10

200

The amount of liquified gas remaining in a cylinder is determined by the ________ of the cylinder

weight

200

When an empty cylinder has been removed from the workstation and stored, it must be marked MT near what area of the cylinder? 

near its top

200

The fuel gas regulator's high pressure gauge usually reads up to __________. 

400 psi

300

When pure oxygen is combined with fuel gases, the pure oxygen produces __________. 

a high temperature flame needed for flame cutting

300

When lifting oxyfuel cylinders always use a ___________.

Cylinder cage 

300

The cutting tips used with liquified fuel gases must have at least _________ preheat holes.

six

300

When welding or cutting metal, wear high-top safety boots that are at least ___________. 

8" tall

300

After adjusting torch on a motorized oxyfuel cutting machine to the desired position, you should __________.

tighten all clamping screws

400

The attachment on the top of a fuel gas cylinder that allows the gas to flow only in one direction is called a __________.

Check valve

400

Safety fuse plugs in the top and bottom of an acetylene cylinder are designed to ________.

release acetylene gas in the event of a fire

400

The regulators used on fuel gas cylinders are often painted red and always have _________ on all connections

left-handed threads

400

Oxyfuel cylinders are under high pressure and should never be exposed to heat in excess of ________.

140 F

400

When shutting down oxyfuel cutting equipment, what should you do after you close the valves on the fuel gas and oxygen cylinders?

Back the regulator adjustment screws out until they are loose. 

500

The first step in selecting a cutting tip is to _______.

Identify the thickness of the material to be cut. 

500

When inspecting a completed cut made with oxyfuel cutting equipment, the drag lines of the cut should be near _________ and not very pronounced. 

vertical

500

when a cutting flame has an excess of fuel the flame is called a __________ flame. 

carburizing

500

The hoses used to carry oxygen from the cylinder to the torch are usually ______.

Green

500

If a cylinder is found to be defective, you should ________.

Place a warning tag on it