General Industry 1
Bonus Questions
Construction 1
General Industry 2
Construction 2
100

Communication equipment necessary for compliance with paragraph (H)(3) and (i)(5) of this section. 

What is .146(d)(4)(iii)?

100

Means a physical hazard or hazardous atmosphere.

What is a Hazard?

100

Develop and implement procedures (such as closing off a permit space and canceling the permit) necessary for concluding the entry after entry operations have been canceled.

What is 1204(I)?

100

Testing and monitoring equipment needed to comply with paragraph (d)(5) in this section

What is .146(4)(i)?

100

Perform pre-entry testing to the extent feasible before entry is authorized.

What is .1204(e)(1)(i)?

200

Develop and implement a system for the preparation, issuance, use, and cancellation of entry permits as required by this section;

What is .146(d)(10)?

200

Identify and evaluate the hazards of permit spaces.

What is 1204.(B)?

200

Lighting equipment needed to enable employees to see well enough to work safely and exit the space quickly in an emergency;

What is .146(d)(4)(v)?

200

Provide at least one attendant outside the permit space into which entry is authorized for the duration of entry operation;

What is .1204 (f)?

300

Isolating the permit space.

What is .146(d)(3)(iii)?

300

Means the process used to identify and evaluate the hazards after an authorized entrant enter the space. This process of checking for changes that is performed in periodic or continuous manner after completion of the initial reading. 

What is monitor or monitoring?

300

Evaluate permit space conditions in accordance with the following paragraphs (e)(1) through (6) of this section when entry operations are conducted.

What is 1204.(E)?

300

Equipment such as ladders, needed for safe ingress and egress by authorized entrants;

What is .146 (d)(4)(vii)?

300

Develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including but not limited to the following: 

What is 1204 (c)?

400

Barriers and shields as required by paragraph (d)(3)(v) of this section.

What is .146(d)(4)(vi)?

400

Aaron Rodger

Who is the Best Qb in the NFL?

400

Ventilating equipment needed to obtain acceptable entry conditions.

What is 1204.(D)(2)?

400

Specifying acceptable entry conditions

What is .146(d)(3)(i)?

400

When testing for atmospheric hazards, test first oxygen, then for combustible gases and vapors, and the for toxic gases and vapors;  

What is .1204 (e)(3)?

500

A condition that is not allowed under the entry permit arises in or near the permit space.

What is .146(e)(5)(ii)?

500

Means an employee who is authorized by the employer to enter a permit space.

What General Industry's definition of an Authorized entrant? 

500

Eliminating any conditions (for example, high pressure) that could make it unsafe to remove an entrance. 

What is 1204.(C)(8)?

500

Review the permit space program using the canceled permits retained under paragraph (e)(6) of this section within 1 year after each entry and revise the program as necessary.

What is .146 (d)(14)?

500

Any other equipment necessary for safe entry into, safe exit from, and recue from, permit space.

What is 1204 (d)(9)?