Safety
Theory
Logic Functions
How Big?
Computers N Stuff
100

This is a electrical charge at rest.

What is Static Electricity?


100

This is the opposition of current flow.

What is resistance?

100

This is a logic function with two normally open input devices in series.

What is AND?

100

This is what determines the size of a Programmable Logic Controller.

What is the number of INPUTS/OUTPUTS?

100

This is what each line of a programming diagram is referred to as. 

What is a Rung?

200

This is clothing and/or equipment worn by technicians to reduce the possibility of injury in the work area.

What is Personal Protective Equipment?

200

This is the rate at which electrons flow through a conductor.

What is Current?


200

This is a logic function with two normally closed input devices in series.

What is NOR?

200

This is the number of I/Os of a LARGE PLC.

What is more than 512?

200

This is the method by which the central processing unit of a programmable logic controller looks at a program.

What is Scan?

300

This is the connection of machinery electrical systems to earth ground to reduce the chance of electrical shock by grounding all non-current -carrying exposed metal.

What is Equipment Bonding?

300

This is the electromotive force in a conductor that allows electrons to flow.

What is voltage?

300

This is a logic function with a normally closed input device controlling power to an output.

That is NOT?

300

This is a PLC with 129 to 512 inputs and outputs.

What is Medium PLC?

300

This in the means by which digital circuits operate that have only two operating states.

What is Binary Signals?

400

This is the process of removing the source of electrical power and installing a lock, which prevents the circuit from being energized.

What is Lockout?

400

This is the positive or negative state of an object's connections.

What is polarity?

400

This is a logic function where two or more normally open input devices are in parallel.

What is OR?

400

This is a Programmable Logic Controller with 16 to 128 inputs and outputs. 

What is Micro PLC?

400

This is a circuit in which the load can be in any operating condition between and including fully ON and fully OFF.

What is analog electrical circuit?

500

This is electrical circuit designed to suppress voltage spikes.  

What is Snubber Circuit?

500

This is the amount of voltage consumed by an input device or output component as current passes through the object.

What is voltage drop?

500

This is a logic function where two or more normally closed inputs are in parallel.

What is NAND?

500

This the number of inputs and outputs in a NANO programmable logic controller.

What is less than 16?

500

This is data in the memory of a Programmable Logic Controller that contains technician developed PLC programs and related information.

What is Program File?