Gravity Always Wins
Current Events
The Toolbox Talk Was About This!
Toolbox of Doom
Potent Potables
100
Top rails on guardrails must be rated for this amount of top and side force?

What is 200lbs?

100

This is the color that we are in for assured grounding this month?

What is green?

100

This is the classification of fire extinguisher that fights electrical related fires.

What is class C?

100

This means.

What is double insulated?

100

This is the new PPC Safety Slogan/Tagline.

What is Safety: Always Planned, Always Practiced, Always Present?
200
This is the distance a warning line must be placed from all leading edges?

What is 15 feet? 

200

This is the voltage OSHA and NFPA 70e states where a shock hazard starts and work is considered energized.

What is 50 volts?

200

Holes or floor openings over this diameter need to be covered, secured, and marked as hole. 

What is 2inches?

200

According to Pieper Policy, this tool can only be operated by a JW with a faceshield and JHA completed. 

What is a circular saw?

200

If you are removing and working above ceiling grid, this is the 2 additional pieces of PPE that should be worn.

What is foam-lined safety glasses and sleeves?

300
This is the maximum arresting force allowed on an employee using a personal fall arrest system.

What is 1,800lbs?

300

These are the two risk assessments that must be completed before working on or around energized parts.

What is Shock and Arc Flash? 

300

According to OSHA, this is the only type of respirator that can be worn voluntarily if Appendix D is acknowledged.

What is N95? 

300

This is the tool to establish an "electrically safe working condition" after LOTO is applied.

What is a multimeter?

300

This is the person on site who is capable of identifying existing and potential hazards and has the authority to take prompt corrective action.

What is a competent person?

400
This is the type/classification of SRL that can be used for foot-level tie-off in a fall arrest scenario?

What is Class 2 or Leading Edge SRL?

400
This is the minimum limited approach boundary for voltages less than 750 VAC (AC).

What is 3feet, 6inches?

400

Confined spaces are spaces where limited means of egress, able to bodily enter, and this condition is met.

What is not designed for human occupancy?

400

This is missing from the tool in this situation. 

What is a tool tether?

400

This means 

What is an oxidizer?

500
This is the clearance distance in feet that must be met before using a conventional 6-foot lanyard.

What is 18 feet?

500

This is the amount of energy that will cause a second degree burn or where 70e considers to be an arc flash hazard (answer in cal/cm2).

What is 1.2cal/cm2? 

500

This is the one type of cave-in protection that is not acceptable for Class C trenches or excavations.

What is benching?

500

This is the Table in the Silica Program that provides exposure control methods for silica. (Table _)

What is Table 1?
500

The OSHA Construction is standard is this part number.

What is 1926?