100

Which type of alternator is used in hydroelectric power stations?

Salient pole alternator

100

The field system of an alternator is usually excited at

250Volts dc supply

100

The number of poles on turbo alternator is usually

2 (minimum)

100

The ratio of starting torque to running torque in a synchronous motor is

1

100

Voltage regulation formula for alternator 

E0-V/V

200

Regulation of an alternator supplying resistive or inductive load is

Always +ve

200

V curve of synchronous generators shows the variation of

Armature current Vs field current

200

Under short-circuit conditions, the power factor of an alternator is

Almost zero lagging

200

Which of the following methods would give higher than actual value of regulation of an alternator?

EMF Method

200

The maximum power developed in cylindrical synchronous machine is occurs at a load angle of

90 degree

300

Distributed winding is preferred over concentrated winding as it

Improves the generated emf waveform from harmonics and adds mechanical strength to the winding

300

The short pitch winding is preferred over full pitch winding for an alternator because it

harmonics can be reduced or totally eliminated

300

To obtain sinusoidal flux distribution, chamfering of poles is done in

Salient pole alternators only

300

The phase sequence of a three-phase alternator will reverse if

The field current remains the same but the direction of rotation is reversed

300

Power factor of an alternator driven by constant prime mover input can be changed by changing the

Excitation of the field winding

400

Armature reaction mmf and leakage reactance of a synchronous machine are determined by ( test )

Open circuit and Zero Power factor Test

400

The synchronous reactance in an alternator is the Combined reactance due to 

leakage flux and armature reaction

400

The reactive power delivered by a synchronous generator can be controlled by

Changing the excitation

400

slip of synchronous motor is

o

400

A synchronous generator is feeding a zero-power factor (lagging) load at rated current. The armature reaction is

Demagnetizing

500

Damper bar used in synchronous motor

starting and eliminate hunting

500

During hunting when the speed becomes super synchronous speed the damper bar develop

induction generator torque

500

An alternator with higher value of SCR has

Better voltage regulation and higher stability limit

500

emf equation of alternator

E= 4.44 f phi N 

500

if alpha is short pitch angle of the winding the coil pitch factor is

cos (alpha/2)