Ancient KCS
The Mind of Harold
The Mind of Chubbs
The Rats Nest
100

disk_led_ctrl

        -s [shelf location. e.g. 0, 1, P1.1, P2.1. If Port number not specified,                                                                              P1 is assumed]

        -D [disk number 1-16 (left to right) for 3U shelf or 1-24 (left to right, bottom to top) for the 4U shelf.

            0 means all disks]

        -f [1 to fail, 0 to clear the fault led]


What is turn on LED beacon?

http://kcs.nimblestorage.com/doc/135

100

Daily Double

Lady Gaga

100

5

What is how many kids does Chubbs have?

This number is not increasing despite popular opinion.

100

The cable between CS-240 to ES1.

What is Legacy SAS to Legacy SAS?

200
  • For CS210 / CS215 / CS220 / CS240 / CS260 / CS420 / CS440 / CS460, the ___________ is amber and this is normal behavior.
  • If the platform is a CS300, CS500, CS700 or later the ________ is green. 
  • Regular blinking indicates that the controller hardware is healthy.
  • Note: The ___ is part of the chassis. If a controller was upgraded from a CS200 / CS400 to a CS300, CS500, CS700 the ______ will remain an amber ___. (i.e. upgrading from a CS260 to CS300)

What is the Heartbeat LED?

http://kcs.nimblestorage.com/doc/43

200

On a Gen5 array, CPLD firmware must be updated prior to completing this.

What is a chassis swap?

200

Shelf Details show this output:

Power supply: Unknown
Cooling fans: Alerted
fan1-A at lower front of controller A: 9919 rpm
fan2-A at lower left rear of controller A: 9715 rpm
fan3-A at lower right rear of controller A: 10055 rpm
fan4-A at upper right front of controller A: 9511 rpm
fan5-A at upper left front of controller A: 9018 rpm
fan6-A at upper left rear of controller A: 9333 rpm
fan1-B at lower front of controller B: 0 rpm <-----
fan2-B at lower left rear of controller B: 0 rpm <-----
fan3-B at lower right rear of controller B: 0 rpm <-----
fan5-B at upper left front of controller B: 0 rpm <-----
fan6-B at upper left rear of controller B: 0 rpm <-----

What is AH-570?

What is BMC issue?

http://kcs.nimblestorage.com/doc/2076

200

The cable from CS500 to ES1

What is HD Mini SAS to Legacy SAS?

300

The customer attempts to perform a software upgrade and the array fails the software precheck on the ___.

  1. Before shipping a new ___reboot the affected controller. If the controller is standby just reboot if active failover.
  2. If the controller boots and the array resumes Active/Standby mode, have the customer perform the upgrade.
  3. If the controller does not boot, see if the customer is willing to re-image the ________ using KB-000208.
  4. If not or if this still fails RMA new ___.

What is the USB precheck error?

What is the USB?

http://kcs.nimblestorage.com/doc/91

300

Reported Symptoms:

  • Array does not return to active standby after are reboot.
  • New array one controller "does not boot"
  • Customer unable to log into the array with admin / admin

Corrective Actions ( non-disruptive )

  • Update Nimble OS to 5.0.7
  • Corrective actions are in KCS-3701

What is RAD failure due to race condition?

300

Gen5 _______ process fails with a FATAL error

What is re-image process?

http://kcs.nimblestorage.com/doc/3556

300

The cable from CS1000 to ES2

What is HD Mini SAS to HD Mini SAS?

400

420-B:/# ____________
Controller fru model does not indicate X9 or CS215 system. ()
T_HD_SIZE=0
T_HD_SIZE=0
T_HD_SIZE=0
T_HD_SIZE=0

  Database Validated.

  There are 2 E5645 CPU(s), with 12 total cores.

  I see 6 DIMM Sockets.
    DIMM Module 1 : 4096 MB.
    DIMM Module 2 : 4096 MB.
    DIMM Module 3 : 4096 MB.
    DIMM Module 4 : 4096 MB.
    DIMM Module 5 : 4096 MB.
    DIMM Module 6 : 4096 MB.

  Number of NICs found: 8
    2 1 Gb NICs.
    2 10 Gb SFP NICs.
    4 10 Gb baseT NICs.

  Found 16 disks: 12 HD and 4 SSD
  Current disk info:
      slot  sd_name  serial              size    capacity    TB  GB
      1     sdp      WD-WMAW31209408     931GiB  1953525168  1   0
      2     sdo      WD-WMAW31290411     931GiB  1953525168  1   0
      3     sdn      WD-WMAW31335742     931GiB  1953525168  1   0
      4     sdm      WD-WMAW31365468     931GiB  1953525168  1   0
      5     sdl      WD-WMAW31365238     931GiB  1953525168  1   0
      6     sdk      WD-WMAW31336111     931GiB  1953525168  1   0
      7     sdj      BTWL3425098K600TGN  558GiB  1172123568  0   600
      8     sdi      BTWL342508Z2600TGN  558GiB  1172123568  0   600
      9     sdh      BTWL342508YZ600TGN  558GiB  1172123568  0   600
      10    sdg      BTWL404201N6600TGN  558GiB  1172123568  0   600
      11    sdf      WD-WMAW31365586     931GiB  1953525168  1   0
      12    sde      WD-WMAW31335606     931GiB  1953525168  1   0
      13    sdd      WD-WMAW31335712     931GiB  1953525168  1   0
      14    sdc      WD-WMAW31334474     931GiB  1953525168  1   0
      15    sdb      WD-WMAW31365394     931GiB  1953525168  1   0
      16    sda      WD-WMAW31283926     931GiB  1953525168  1   0

400

FC card negotiates at 8Gb instead of 16Gb

What is AS-92593?

What is FC firmware?

http://kcs.nimblestorage.com/doc/3599

400

HF/AF20 are single processor systems requiring the BIOS PCI settings to be set in a particular way. This setting was not properly set on some RMA parts and new systems resulting in the controller not booting to Nimble OS.

The controller will not boot to NimbleOS or will enter a panic/reboot loop on the initial turn up.


What is Incorrect bifurcation settings HF/AF20

http://kcs.nimblestorage.com/doc/3407

400

The cable between ES1 to ES2 shelf to shelf

What is HD Mini SAS to Legacy SAS?

500
  • Refer to the power supply troubleshooting Guide
  • ______________ output in the ctrl_info.txt of an autosupport contains information regarding the controller power supplies.
  • Summary of states:
    nc == not connected (expected ____ slave state)
    cr == critical error (this indicates there is a failure, check LED status and reseat/replace)
    ok == Working fine (expected ____ master state) 
  • If two power supplies are marked failed on the controller shelf there are multiple possible causes.
    • Wedge BMC communication
      • This will result in Dual missing power-supplies or both power supplies reporting as failed.
    • Down rev PSUs: This issue has not been seen in multiple years.
      • Those need replacing. check this  KCS article  (Dual PSU failure reporting error)

What is IPMI sensor output?

What is ipmitool sdr?

http://kcs.nimblestorage.com/doc/275

500

Both controllers reboot during UPS testing

Reported Symptoms: 

  • Customer reports that the array is not surviving cut over to UPS / Generator.

  • Both controllers reboot unexpectedly during UPS on battery/voltage correction event.
  • So far we have had various symptoms in the customer environment.
  • During the transfer to UPS as part of a power event or testing the Gen5 array does not hold up.

  • Both controllers reboot when testing UPS

What is AS-90911 - Array does not hold up when switching over to UPS?

500

One was a salted

What are two peanuts walking down the street?

500

This __ meter cable is not supported on P2 of X9 controllers

What is 3?