General Regulations & Safety
Fixtures, Faucets & Fittings
Water Heaters
Water Supply & Distribution
Sanitary Drainage & Vents
100

This is the minimum depth, in inches, that exterior water supply system piping must be installed below grade

What is 12 inches

100

 This is the minimum required clearance, in inches, in front of a water closet, bidet, or lavatory to any wall, fixture, or door

What is 21 inches?

100

These must be installed at the bottom of each tank-type water heater for the purpose of emptying the vesse

What are drain valves?


100

This is the minimum diameter allowed for a water service pipe

What is 3/4 inch?

100

This is the minimum slope per foot required for horizontal drainage pipe that is 2.5 inches or smaller in diameter

What is 1/4 inch per foot?

200

This type of protective plate must be used in concealed locations when piping (other than cast iron or galvanized steel) is installed through holes in studs less than 1.25 inches from the edge

What is a steel shield plate

200

To ensure sanitary conditions, the IPC specifically prohibits the installation of drinking fountains, water coolers, and water dispensers in these rooms

What are public restrooms?

200

Temperature and pressure (T&P) relief valves must have a temperature setting that does not exceed this many degrees Fahrenheit

 What is 210°F

200

 This color is used to identify reclaimed, rain, and graywater distribution systems and their associated identification tape

What is purple?

200

The primary function of this system is to protect every trap against the loss of its seal

What is the venting system?

300

For plastic sewer piping, this insulated copper conductor must be installed adjacent to and over the full length of the piping for location purposes

What is a tracer wire

300

This is the maximum allowed temperature, in degrees Fahrenheit, for water discharged from a bidet fitting

What is 110°F

300

A level working space of at least this size, in inches (length by width), must be provided in front of the control side to service a water heater

What is 30 inches by 30 inches?

300

 An approved pressure-reducing valve is required when the static water pressure within a building exceeds this many psi

What is 80 psi?

300

 These types of joints for stainless steel drainage systems must be made with an approved elastomeric seal

 What are O-ring joints?

400

 Trenching installed parallel to these building elements shall not extend into their bearing plane, which is defined by a 45-degree angle from their outside bottom edge

What are footings and walls

400

In employee and public toilet facilities, this specific fixture is required to be located in the same room as the water closet

What is a lavatory

400

The temperature relief valve sensing element must be located within this many inches of the top of the water heater tank

What is 6 inches

400

When water service and building sewer pipes are in the same trench and not constructed of specific materials, they must be horizontally separated by at least this many feet of undisturbed earth

What is 5 feet?

400

Every dry vent must rise vertically to a point not less than this many inches above the flood level rim of the highest fixture being vented

What is 6 inches?

500

According to Table 308.5, this is the maximum horizontal hanger spacing, in feet, allowed for 1-inch and smaller CPVC pipe

What is 3 feet?

500

When used for shower lining, this material must weigh at least 4 pounds per square foot and be coated with asphalt paint

What is sheet lead

500

 These specific safety devices must be installed on bottom-fed water heaters to prevent the tank from siphoning

What are vacuum relief valves?

500

The developed length of hot or tempered water piping from the source of heated water to the fixtures shall not exceed this distance

What is 50 feet?

500

 Soil and waste stacks in buildings having more than this many branch intervals must be provided with a relief vent at every tenth interval

What is 10 branch intervals?