Waste
H2O
Drain
Water
Random
100

What is the minimum size of a stack that can go through the roof?

3 inch

100

The softening agent used to soften water is called?

Brine

100

The term "solvent weld" applies to what type of material?

Plastic

100

Hard drawn copper tubing one-inch or smaller when installed horizontally shall be supported every how many feet?

8 feet

100

True or false? All shower valves should have a temperature balance control?

True

200

The minimum size for a gravity underfloor building drain line is?

 4 inch

200

Water which is safe for people to drink and cook with is referred by code as ________ water

Potable

200

The maximum developed length for any indirect waste of any sanitary waste line shall not exceed how many feet?

5 feet

200

What is the minimum length an air chamber for a fixture should be?

12 inches

200

True or false? A residential dishwasher may discharge directly into a food waste disposal unit?

Fasle

300

A common cause of trap seal loss in a plumbing fixture trap due to siphonage is?

A clogged vent pipe

300

Are push-on angle stop valves allowed by code in Illinois?

Yes

300

The total number of water closets that may be installed on a three inch vertical stack is?

2 per interval

300

Non potable water piping shall be permanently marked or identified by a distinctive color, so that the piping is easily distinguished from potable water piping, what color should it be?

Purple

300

No shower stall or receptor for a single family house shall have a finished outside dimension which is less than?

32 inches

400

The minimum size vent allowable by the Illinois plumbing code is?

1 1/4 inch

400

What is the minimum water supply service pipe for any building?

3/4 inch

400

What is the minimum size vent for a water closet?

2 inches

400

The minimum constant water service pressure on the discharge side of the water meter must be at least how many psi?

20 psi

400

What must be installed at a water heater when their are fixtures below it?

A vacuum breaker

500

Plastic pipe, when installed horizontally, shall be supported at intervals not to exceed

Four-feet

500

Below what temperature is considered cold water?

85 degrees Fahrenheit

500

A cleanout shall be provided at no more than _______ from the base of a stack?

4 feet

500

The maximum temperatures of any water discharging into any part of the drainage system is?

180 degrees

500

Adding a backflow device to water supply system creates what type of system?

Closed system