How often is an OQI Outgoing Quality Inspection required.
What is within 1 hour of SU & E4H
True or False: Glue on cans is considered on automatic block.
What is False? Must be blocked if the glue is on the lid OR greater than 1/2 inch
This is a picture of a flagging label. What is the blocking specification for flagging labels?
What is >1/4" single or cumulative
How many open flaps found on a pallet initiate a block
What is 1 or more open flaps
The policy for partial pallets when a blocking is packing out
What is partial pallets are not permitted and the last pallet from each palletizer needs to be made into a full pallet unless the follow scenario occurs:
How often is the Stretch Wrap Tension check performed.
What is SU & E8H
The blocking specification for dents on cans
What is >1" cumulative
This is a picture of a torn label. What is the blocking specification for torn labels?

What is >1/4" single or cumulative
The following photo is carrier scuffing. What is the block specification for scuffing on a carrier/carton?

What is >1/2" cumulative
While preforming a Packer Process Quality check what code is entered into the IMS PQC applet below?

What is the code of the carrier / carton of the case being inspected
How many can or bottles are inspected in each case for an OQI Outgoing Quality Inspection check
What is every can or bottle in the case.
The blocking specification for scratches on cans
>1/2" cumulative
What is the blocking specification for Vertical or Horizontal Pleat/Wrinkle for body and back labels?
What is >1/8”
How much Foreign Matter is permitted on Carrier/Carton?
What is None
If defects are found during a check are comments required
What is Yes... for critical and non-critical defects comments are required to be entered in the check. In addition, critical defects are required to be entered into the defect category section

How many times do you lift and drop Single Handle Carriers and Double Handle Carriers while performing the Jerk Test?
What is 6 times for Single Handle Carriers (Three times for both directions of case) and 6 times for Double Handle Carriers
How many critical dented / scratched cans found in a case will initiate a block
What is
How many critically torn labels are permitted in a case before a block?
What is 4% (ex: 1 critical defect in a 24-bottle case is 4.2%)
When is a block required for Carrier Flap Alignment (Misaligned Flaps)?
What is if alignment is >3/8"
or any exposed internal flap graphics (glue targets, non-colored carton)
While preforming a Packer Process Quality check what code is entered into the IMS PQC applet below?

What is the code from the label of the bottles in the case that is being inspected
If I am missing this part of the code, I have to block...
What is the brewery or date code
How many critically flagging labels are permitted in a case before a block?
What is 4% (ex: 1 critical defect in a 24-bottle case is 4.2%)
How much Foreign Matter is permitted on Carrier/Carton?
What is None
When ending a block at the palletizers, this is the information that needs to be provided to QA
What is...
1. The last pallet from each palletizer is off the palletizers and all rewrap stations and heading to HDS
2. The barcode off the last pallet from each palletizer going into HDS
3 If there is or is not a partial pallet
Do both sides of the case need inspected and opened when performing the OQI
What is YES
Is a partial glue bead on a MAJOR flap a block?
What is True.
Is it okay to leave a block pallet sitting at the palletizers after the block has finished packing out for extended periods
What is No. Blocked pallets should not sit at the palletizer for extended periods of time.
Is the following code considered legible?

What is NO... codes are not to be printed on the graphics.