General
Configuration
More General
Over/under
Even More General
100

The single function of an AEC is to eliminate the need to set

What is time?

100

When an AEC is used for an AP abdomen, this/these ionization chamber(s) are utilized

What are all 3?

100

U.S. public law requires that generators automatically terminate AEC exposures at ____ mAs above 50 kVp

What is 600?


100

If the collimated light field cuts through and does not completely cover an activated AEC chamber, the result will be an ___________ exposed image

What is over exposed?

100

AEC's have a minimum reaction time of less than _______ seconds

What is .001?

200

When using an AEC, the radiographer loses control of

What is mAs?

200

When an AEC is used for an AP lumbar spine, this/these ionization chamber (s) are utilized

What is center cell?

200

Early versions of AEC technology were referred to as

What are phototimers?

200

If the part is smaller than an activated chamber, the image part will be _____________

What is underexposed?


200

When a radiologist desires an image that is under or overexposed, this should be adjusted

What is the density setting?

300

Ionization chamber AECs are usually used in a ____ chamber configuration.

What is 3?

300

When an AEC is used for an AP hip, this/these ionization chamber (s) are utilized

What is the center cell?

300

In the event that the mAs needed for a small anatomical structure is very small, in order to ensure the AEC terminates the exposure correctly, the _________should be decreased

What is mA?

300

When performing a right shoulder x-ray using AEC, selection of the upper right cell will result in an image that is ___________

What is underexposed?

300

Chambers cannot tell the difference between primary and scatter radiation, is a high proportion of scatter radiation reached the chambers, the exposure will terminate ________

What is early or prematurely?

400

When more than one ionization chamber is used simultaneously during exposure, the signal is:

What is averaged?

400

When an AEC is used for a PA chest, this/these ionization chamber (s) are utilized

What are the upper right and left?

400

Most modern AEC systems provide a minimum response time of

1 millisecond

0.001 sec

1/1000 sec

400

When performing a right shoulder x-ray utilizing the center cell, if you accidentally select a lumbar spine in the anatomical programming, the image will be ________

What is overexposed?

400

Identify the portion of the ionization chamber that is labeled red

What is the electrode?

500

The backup time of most AECs is set at ____ of the anticipated manual exposure time.

What is 150%?

500

When an AEC is used for a foot, this/these ionization chamber (s) are utilized

What is AEC IS NOT USED FOR SMALL EXTREMETIES?

500

A radiographer is performing an AP knee radiograph using AEC. The manual technique for this exam would be 12 mAs at 80 kVp. The backup mAs the radiographer should set would be?

What is 18 mAs.

500

When using AEC for a lumbar spine, you select the center cell however your patient is not centered properly and the spine is not centered directly over the cell, your image will be _________

What is underexposed?

500

What technologist error resulted in this overexposed chest xray?

What is center cell selection?