VAV Diffusers
Noise Control
Displacement Ventilation
Controls
Overhead Mixed Air Distribution
100

This is a copper bulb filled with wax and acts as a motor and thermostat for mechanical VAV diffusers.

What is a thermostatic actuator?

100

This space or application is typically where a packless silencer is used.

What is an OR or chemical fume hood?

100

This is the ideal location for a ceiling mounted displacement diffuser.

What are Transient areas?

100

The location of where Price Controls are manufactured.

What is Price Electronics, Winnipeg, Canada?

100

These are the two primary zone types in every underfloor project.

What are Interior and Perimeter zone?

200

This is the number of additional digital drone diffusers that can be daisy chained off a single master diffuser. 

What is 5 drone diffusers?

200

This casing material should be used for silencers in pool or natatorium settings.

What is Aluminum?

200

This special should be specified for applications where the diffusers may get hit.

What is Heavy duty construction?

200

This is the communication protocol that is used within a Price Networked Voting System.

What is BACNET MS/TP?

200

This is the most cost-effective solution for perimeter applications.

What is LNT?

300

This is the pressure range (inches of static) that VAV Diffusers should be operating within.

What is 0.05" to 0.25"?

300

What occurs when silencers are not installed in ideal conditions.

What is system effect?

300

This is the parameter by which we size displacement diffusers_____.

What is 40fpm face velocity?

300

The acronym PIC means this:

What is Price Intelligent Controller?

300

This diffuser type should be used to maximize comfort in the occupied space.

What is Displacement style (MFD-DP)?

400

This is one of the two primary benefits of individual thermostats.

What are small zones of control and individual set points? (Either one)

400

These are 3 different ways to search for and select silencers in AIO.

What are Performance, Design Criteria, and Price Model Number?

400

This is the minimum face area for an architectural face placed in-front of a displacement diffuser.

What is 50%?



400

These are the types of rooftop units/applications the PRTU is designed to control.

What is Constant Volume, Variable Volume, & Heat Pump applications?

400

This sensor is critical to the success of every underfloor project.

What is a Plenum Pressure Sensor?

500

These are two of the four benefits of high diffuser discharge velocity.

What are Coanda, throw, entrainment, and mixing? (Any 2 of these 4)

500

This describes the sound that Sources produce, independent of path or environment.

What is sound power (Lw)?

500

The Ventilation effectiveness for ceiling heights above 18ft.

What is 1.5?

500

The suggested building size/recommendation for the Price Zoning System.

What is small to medium sized buildings? 

Bonus - 50,000 sqft, 2-30 ton rooftops

500

This is what the performance of your displacement diffuser is based on.

What is Design plenum pressure?