FFU
Diffusers
Ceiling Systems
HEPA Filtered Diffusers
Air Purification
100

The BACnet Flow Controller has these (3) operating modes

What is Local, 10 VDC BAS, and BACnet?

100

This distance is recommended between a HORD diffuser and laminar flow diffuser

What is 2 feet?

100

This ceiling panel type/style is recommended in boom location areas

What is the SCF

100

This action would compromise filter media when installing the filter

What is touching the media

100

This CE Price air purifier can be mounted in the ceiling or placed on the floor

What is Puraflo?

200

Up to this number of Fan Filter Units can connect to (1) Price wall mounted speed controller

What is 30?

200

This CE product is required to surface mount a non-flanged diffuser

What is HGMF framing?

200

This main feature can be found in the Ultrasuite but not the Hospital Grade Common Plenum

What is LED integration?

200

Filter loading is monitored with this face mounted device

What is the LED indicator?

200

Relative to a dental patient’s body, this is the location where a return grille should be installed

What are the patients’ feet?

300

This document is the location where you would find the max/full load amp information for a Fan Filter Unit

What is the FFU Submittal?

300

FRFD has these (2) airflow patterns

What is 2-way Full Radial, 1-way Half Radial

300

The Ultrasuite with no HEPA has a minimum plenum height as low as this number

What is 12”?

300

This port is used to measure plenum static pressure as well as sample aerosol concentration above the filter

What is the Aerosol Sample Static Pressure Port (ASSP)?

300

These three different air purification technologies can be used in the Price Room Air Purifier (RAP)

What is HEPA, BPI, an UVC?

400

This motor program is used when a fan filter unit is ducted and there is an upstream VAV device

What is the constant Torque motor program?

400

The correct airflow orientation of a Radial Flow Diffuser when installed near a fume hood

What is perpendicular?

400

These types of driver cabinets must be surface mount installed with louvered sides along horizontal

What is 600W and Lutron driver cabinets?

400

These two installation styles is possible with the FDM

What is exposed and recessed?

400

These air purification devices are ideal for use in pandemic-ready patient rooms

What is the CARES unit or Puraflo Dual-Outlet?

500

This wheel type can be used with both Constant Torque and Constant Flow motor programs

What is Forwards Curved (FC) wheel?

500

This airflow pattern is required in ISO 5 and cleaner cleanrooms

What is Unidirectional airflow

500

Defined in ASHRAE 170, one of these types of OR or Class 3 rooms shall provide HEPA filters in the terminal device

What is Orthopedic, Transplants, neurosurgery, or dedicated burn unit procedures
500

People have this general misconception about the MPPS when reading the filter efficiency rating

What is the most efficient particle size rather than it being the worst efficient

500

An occupancy sensor can be found on this Price air purifier

What is the CAP?