Formulas
Distortion
Grab Bag
Grids
AEC
100

How do we calculate SID?

OID + SOD

100

What is the one type of size distortion?

Magnification

100

What x-rays are those that exit from the patient?

Remnant 

100

Who invented the grid?

Gustave Bucky

100

What are the two types of AECs?

Ionization chamber or phototimer

200

mAs x to/from is the formula for what?

Grid conversion

200

What are the two types of shape distortion?

Foreshortening and elongation 

200

How does a short scale of contrast look on a radiograph?

Black and white with limited shades of gray

200

What technique could be done in place of a grid to reduce the amount of scatter reaching the IR?

Air Gap Technique

200

What are 3 out of the 5 things that must be set on your control panel when using AEC?

kVp

mA

back up time

density

detector selection 

300

What is the Inverse Square Law?

I1/I2=D22/D12 

300

What shape distortion that occurs when the image is longer than the true object?

Elongation

300

Changing the kVp by 15% has the same effect on exposure to the IR as changing the mAs by a factor of what?

2

300

When are grids used (2 answers)? 

When the part is: 10 cm (4 inches) or greater in thickness and when using over 70 kVp

300
Your back up timer should be set at what percentage the expected exposure time for anatomy?

150-200% above the expected exposure

400

What number is assigned to a 8:1 grid when performing the grid conversion formula?

4

400

What shape distortion occurs when the image is shorter than the true object?

Foreshortening 

400

What technique chart is preferred because body parts will be penetrated and contrast will be consistent? 

Fixed kVp/variable mAs

400

What grid error occurs when the x-ray beam is not centered side to side with the center of a grid?

Off-center error

400

What is one cause of overexposure when using AEC?

Wrong bucky selected

Improper cell selected (cell under a thicker part)

Presence of artifacts

Density control left on a "plus" setting

Exposure time needed is less than the minimum response time

500

How do we calculate the magnification factor?

SID/SOD or Image size/Object size

500

How will a larger SID affect size distortion?

Less magnified

500

What is a measure of the imaging system's ability to accurately display small anatomic objects having high spatial frequency?

Modulation transfer function

500

What is the absorption of the primary beam, reducing the number of photons reaching the IR, mainly occurs with "focused" grids?

Grid cut-off

500

What is one cause of underexposure when using AEC?

Not enough collimation

Improper photocell selected (cell under a thinner part)

Anatomy is near the edge of the body

Anatomy not centered over the photocell

Back up time is set too short for the time needed

Density control left on a "minus" setting