PERSONAL PROTECTION
BRING THE HEAT
IN THE HOOD
CHEMICAL ADDICTION
CURRENT AFFAIRS
100
Both of these are required annually for BTEC personnel who use a face mask/respirator.
What is refresher training and fit testing
100
The temperature at which a substance can vaporize to form an ignitable mixture in air
What is flash point
100
The distance required to be maintained by all apparatus from the back of the face of a fume hood.
What is SIX INCHES
100
Ignites spontaneously at <130F in air
What is a pyrophoric substance
100
A phenomenon that can cause serious injury or death, temperatures in excess of 35,000F, and blast pressures of over 2000 lbs./sq. ft.
What is electrical arcing or an arc flash
200
These are generally required in higher risk process areas and consists of at least flame retardant long sleeved shirts and pants or long sleeved coveralls.
What are Level 1 FRCs
200
Gasoline, oil, paint, and other flammable liquids are extinguished using this type of fire extinguisher
What is type B fire extinguisher
200
This type of hood is generally suitable for operations using PHS materials, materials with TLV's less than 100 ppm and/or flash point less than 100ยบ F
What is Type 1A
200
These materials must be dated when opened and disposed of when required as per safety manuals
What are peroxidizable chemicals or peroxide formers
200
Minimum distance required to be maintained by personnel when working around a 50Kv line
What is 10 ft.
300
THE LIMIT OF NOISE OVER WHICH HEARING PROTECTION IS REQUIRED
What is 85 dBA
300
Lowest temperature required to cause self sustainable combustion without initiation by an external ignition source
What is Autoignition temperature
300
The inert gas supply to a gloved dry box must have this set at no more than 30 psig
What is safety relief valve
300
A colorless, flammable, extremely hazardous gas which paralyzes the sense of smell at hazardous concentrations.
What is Hydrogen Sulfide.
300
A fast acting device that senses small imbalances in a circuit caused by current leakage to ground
What is GFCI (Ground Fault Circuit Interrupter)
400
Direct ventilation in safety goggles prevents this
What is fogging
400
Fuel, oxygen, uninhibited chemical reaction, and source of ignition constitute this
What is a fire tetrahedron
400
This section has the overall responsibility of supplying the training for the laboratory fume hood program, reviewing the program annually, and revising the program as needed.
What is Industrial Hygiene
400
This gas was used by the Romans in wine making, and ExxonMobil OEL (Occupational Exposure Limits) 8-hr TWA (Time Weighted Average Limit) for this compound is 0.5ppm
What is Sulfur Dioxide
400
This is found at voltages of 10 Kv and higher, and it is very destructive to natural rubber under mechanical stress
What is Ozone
500
Safety eyewear complies with this standard
What is ANSIZ.87 or Z-87.1
500
The range for this class of extinguisher is about 8-10 ft at starting pressure
What is a class C fire extinguisher
500
The acceptable range of average face Velocity (FPM) for a type B hood
What is 60-79 FPM
500
Preferred means for controlling chemical exposures as per BTEC's chemical management plan
What are engineering controls
500
The number of days at BTEC without an on-the-job injury
What is 946 days