Show:
Questions
Responses
Print
Farris Contacts
Farris History
Terminology
Design & Operation
Marketing
100
She is the Aftermarket Manager for Farris Engineering
Who is Pat Ewaska
100
The year Farris Engineering was founded
What is 1943
100
The inlet pressure at which the pressure relief valve is adjusted to open under service conditions.
What is Set Pressure
100
Maximum operating to set pressure ratio for spring loaded PRVs.
What is 90%
100
The Marketing Manager at Farris Engineering
Who is Cindy Andersen
200
Day-to-day (MRO) inquiry and technical issues should be addressed to this group
Who are Customer Service Representatives (CSRs)
200
The founder of Farris Engineering
Who is Victor Farris
200
The difference between set pressure of a pressure relief valve and re-seating pressure expressed as a percentage of set pressure.
What is Blowdown
200
The initial audible discharge through the PRV (Pfffffft!)
What is Simmer
200
Provides an overview of Farris Engineering: The Company, Farris Total Pressure Relief Management Solutions, Software Solutions and Products
What is First Line Of Safety (FLOS)
300
This group enters project orders and administers them through shipment
What is the Project Contract Administrators (PCA) Group
300
Where is Farris Engineering's headquarters located?
Where is Brecksville, Ohio.
300
The pressure increase over the set pressure of a pressure relief valve, usually expressed as a percentage of set pressure.
What is Overpressure
300
As system pressure nears set pressure, the closing forces increase
What is a Pilot Operated Valve
300
Introduced this year in a plastic, lightweight design for customer visits and local trade shows
What is a 2600 Cutaway
400
Who is the Global - North American Sales Manager for the Curtiss-Wright valve group?
Who is Gabe Salwan
400
Name two countries (other than the U.S. and Canada) where Farris Engineering has a Sales Office
Where is Brazil, England, India and China
400
The pressure increase over the MAWP of the vessel during discharge through the pressure relief valve, usually expressed as a percentage of MAWP.
What is Accumulation
400
Used when the built-up back pressure exceeds the allowable accumulation (or 10% as an industry rule)
What is a Balanced Bellows Valve or PORV
400
The only "official" logo for use by representatives in documents, web sites, etc.
What is the red Circle Farris Logo
500
Should be contacted for low pricing approval, customer visits, lunch & learns
Who are Regional Sales Managers (RSMs)
500
The company that owned Farris Engineering before it was sold to Curtiss-Wright
What is Teledyne (Allegheny-Teledyne)
500
Pressure existing at the outlet of a pressure relief valve occasioned by the flow through the valve into a discharge system.
What is Built-up Back Pressure
500
Opens in proportion to overpressure up to about 5%; then opens fully.
What is a Modulate Action PORV
500
Where literature is ordered
What is CW Commerce