Quality 1
Quality 2
Quality & Processes
Processes 1
Processes 2
100

Before using a tool for a critical measurement, the tool may be required to be__________.

a)Tempered

b)Calibrated

c)Certified

d)Signed off

Calibrated

100

Which measurement tool should be selected to measure a part with a lengthspecification of 2.125 +/- 0.006 inches?

a)Protractor

b)Gauge block

c)Caliper

d)6-inch rule

Caliper

100

A micrometer measures length to an accuracy of __________.

a)0.1 inch

b)0.01 inch

c)0.0001 inch

d)0.001 inch


0.0001 inch

100

Which of the following does the programmer define as the origin ofmeasurements on the workpiece?

a)Part zero point

b)Machine zero home

c)Tool reference point

d)Work offset


Part zero point

100

M-codes are NOT __________.

a)Miscellaneous machine commands

b)Typically used to turn machine functions on and off

c)Codes that can alter the sequence in which the blocks are executed within the part program

d)Used to set the mode of operation

Used to set the mode of operation

200

Calibration means to __________.

a)Create an SPC file

b)Set an instrument to zero

c)Adjust a control chart

d)Adjust a device to a standard

Adjust a device to a standard

200

Calibration of measuring instruments is important because it ensures that theinstrument is __________.

a)Working

b)Properly installed

c)Safely installed

d)

Calibration of measuring instruments is important because it ensures that theinstrument is __________.

a)Working

b)Properly installed

c)Safely installed

d)Accurate

Accurate

200

On a horizontal number line, positive numbers are to the __________ of zero.

a)Left

b)Right

c)Top

d)Bottom

Right

200

The distance along each axis from the machine zero home position to theprogrammed reference point is known as the __________.

a)Tool offset

b)Axis origin

c)Tool wear offset

d)Work offset

Work offset

200

What portion of the part program follows the toolpath blocks?

a)Startup block

b)Program safety block

c)End block

d)Program number

End block

300

Company standards determine how often __________ is performed.

a)A lockout/ tagout

b)Calibration of hand tools

c)An OSHA inspection

d)Calibration of surface finish gages

Calibration of surface finish gages

300

What should be done every time before taking a measurement with dial calipers?

a)Reset the display

b)Have the calipers certified

c)Check the calibration

d)Nothing needs to be done

Check the calibration

300

Which micrometer scale is printed vertically around the left edge of thethimble?

a)Sleeve

b)Vernier

c)Zero

d)Thimble

Thimble

300

Sets of values used to determine the location of the tool tip relative to the programmed reference point are known as __________.

a)Orders

b)Offsets

c)Scalars

d)Magnitudes


Offsets

300

Before running a CNC program the operator should __________.

a)Execute the toolpath block

b)Home the axes

c)Check coolant level

d)Remove the tool from the spindle

Home the axes

400

Precision measuring equipment that has been mishandled should be__________.

a)Used anyway

b)Sent out for recalibration immediately

c)Checked against a gauge blockor known good tool for accuracy before using

d)Discarded

Checked against a gauge blockor known good tool for accuracy before using

400

What is the total caliper measurement equal to?

a)Scale reading + dial reading

b)Scale reading - dial reading

c)Scale reading × dial reading

d)Scale reading / dial reading

Scale reading + dial reading

400

The Cartesian coordinate system is __________.

a)A program for designing parts

b)A mathematical grid that identifies points on a plane or in space

c)A computer that controls machine movements

d)The method used for tool changing

A mathematical grid that identifies points on a plane or in space

400

Manual data input, computer-aided manufacturing, and conversational are all__________.

a)Machine types

b)Programming methods

c)CNC components

d)G-codes

Programming methods

400

Which of the following is NOT included in the start blocks?

a)Start of program symbol

b)Machining operations

c)Program number

d)Program comment

Machining operations

500

Technicians use instrument reliability to determine __________.

a)How many instruments to use tomeasure a signal

b)Calibration intervals

c)Sampling plans

d)SPC lot size

Calibration intervals

500

SPC data can be collected and transferred to a PC from what device?

a)A mouse

b)A digital caliper

c)A printer

d)A disk drive

A digital caliper

500

What device is used to test a micrometer's calibration?

a)Gauge blocks

b)Calibrator

c)Test part

d)Reference part

Gauge blocks

500

G-codes are __________.

a)Miscellaneous commands

b)Spindle commands

c)Preparatory commands

d)Coolant commands

Preparatory commands

500

CNC program moves are contained in the __________ block.

a)Start

b)End

c)Toolpath

d)Run

Toolpath