Assets & Consumables
Methods & Training
PTS
Problem Solving
Blocking
100

I must be calibrated to ensure that my results are accurate.

What is Quality measuring equipment?

100

I am the tool used to determine if a person who does quality tests are competent to perform the test.

What is OWD (operational work diagnosos)?

100

I am the tool (paper or electronic) used to record the information captured from all PTS checks.

What is the data sheet?

100

I am used to determine when a problem solving must be initiated by frontline

What is a 5-whys trigger?

100

I am affixed to blocked product to communicate the status.

What is a blocking label?

200

If must be applied if to the equipment if it is not working properly.

What is an Out of Service label/sticker?

200

I am the location where the methodologies and reaction plans must be located  for technicians and operators to access them.

What is the (OWS) Operator Work Station?

200

If I am out of the green zone then there is the potential for unsafe food.

What is a CCP (Critical Control Point)?

200

I am the technology tool used to capture 5-whys.

What is Problem Terminator?

200

I am the number of rules that exist for blocked product.

What is the number four?

300

The rules and guidelines that govern all areas where quality analytical testing is done.

What is the Phys-Chem Laboratory Policy?
300

I must include the safety hazards associated with performing any quality test.

What is the analytical standard or method?

300

I am the tool used to respond to any parameter that is not in the green zone.

What is the PTS reaction plan?

300

In the problem-solving relay, I am the tool selected to help monitor a process from shift to shift. When I am green its time to move on.

What is a dynamic PI?

300

I am the KPI used to measure how well blocking is applied.

What is blocking compliance?

400

I am a list of questions that must be asked to check if the results obtained are accurate and valid.

What are the verification rules?

400
I am the period of time within which all analytical procedures must be revised.

What is three years?

400

I am triggered whenever there is non-conforming product generated.

What is the Blocking Procedure?

400

I am the problem-solving tool used to assess issues that are in the manage to sustain level.

What is the SDCA Cycle?

400

I am the time period within which full blocking must be completed.

What is by the following shift?

500

I must be labelled with my name, the date I was made, my expiry date and any hazards I have.

What is a chemical used for testing.

500

I am the tool used to assess the competence of person who perform analytical quality tests?

What is FAC (formative assessment checklist)?

500

I am the highest category of parameter within the PTS.

What is an RCI (Release Control Item)/ CCP (Critical Control Point)?

500

I am the second level of tool used if the same problem is recurring without resolution.

What is an abnormality report?

500

I must be assessed each month by the first or second week.

What is the MAZ Blocking Policy Checklist?