A
B
C
D
E
100

Eaves over required window shall not be less than ______ millimeters from the side and rear property line.

750 mm

100

Ventilation or vent shaft shall have a horizontal cross-sectional of not less than 1.0sq. meter for every meter of height of shaft but in no case shall be the area be less than 1.0sq. meter. No vent shaft shall have at least dimension less than __________ millimeters.

600 mm

100

Which group does Storage and Hazardous type of Occupancy Belong?

Group G

100

The live load of the first floor shall be at least ________ per square meter

200 kg

100

What Group of Occupancy a Mental Hospital Belong?

Group D-Institutional

200

Footings shall be of efficient size and strength of support the load of the dwelling and shall be at least ___ millimeters thick and ___millimeters below the surface of the ground

250mm ; 600mm

200

The wind load for roofs shall be at least __________ per square meter for vertical projection.

120 kgs

200

Mezzanine floors shall have a clear ceiling height not less than ________ above and below it.

1.80 m 

200

All electrical installation shall conform to the requirements of the______________.

Philippine Electrical Code

200

Stairs shall be at least ________ in clear width, with a rise of 200 millimeters and a minimum run of 200 millimeters.

750 millimeters

300

Under the NBC, prisons shall be classified under what occupancy classification

Group D-Institutional

300

Any assembly building with a stage and an occupant load of less than 1000 in the building is under what group of Occupancy? 

Group H -  Assembly Other Than Group I

300

Nursing homes for ambulatory patients, homes for children of kindergarten age or over, each accommodating more than five persons are under Group D occupancy under what Division? 

Division 3

300

Business and Mercantile is under what group?

Group E

300

minimum ceiling height of the first storey and floor with Natural Light and Ventilation shall be _______ 

2.70 meters

400

When a building is of mixed occupancy or used for more than one occupancy, the whole building shall be subject to the most ___________ pertaining to any of the type of occupancy found therein

Restrictive Requirement

400

Under the NBC, School rooms/Classrooms with natural ventilation shall have a minimum air space per person of? 

3.00 cubic meters

400

Rooms intended for any use, not provided with artificial ventilation system, shall be provided with a window or windows with a total free area of openings equal to at least______ of the floor area of the room.

10 %

400

Building Height Limit for Residential 1 (R-1)

10.00 m

400

Minimum air space for Workshop, Factories, and Offices is ______ of air space per person

12.00 cubic meters

500

Courts, yards, and light wells shall be measured clear of all projections from the walls enclosing such wells or yards with the exception of roof leaders, wall copings, sills, or steel fire escapes not exceeding ______ in width.

1.20 meters

500

All inner court shall be connected to a street or yard, either by a passageway with a minimum width of _____ meters or by a door through a room or rooms.

1.20 m

500

No building shall be constructed unless it adjoins or has direct access to a __________? 

public space, yard or street

500

What do you call the maximum height to be allowed for buildings/structures based on their proposed use or occupancy; the ______ is generally determined after the application of other development controls?

BHL or Building Height Limit

500

Illustrate an INSIDE LOT