Procedures
Image Acquisition
Radiation Protection
Patient Care
Wild
100

The term that refers to parts away from the source or beginning is:

Distal

100

Window level adjusts the _______.

Brightness

100

The Gray is the unit of:

Absorbed Dose

100

The most common healthcare associated illness (HAI) is a:

UTI

100

The maximum number of electrons in the valance shell:

8

200

Deoxygenated blood from the head and thorax is returned to the heart by the:

Superior Vena Cava

200

The absorption of useful radiation by a grid is called:

Grid Cutoff

200

The reduction in the intensity of an x-ray beam as it passes through material is termed:                

Attenuation

200

A patient who is diaphoretic is experiencing:        

Profuse Sweating

200

The photoelectric effect is an interaction between an x-ray photon and:

An Inner Shell Electron

300

An aspirated foreign body is more likely to enter the lower respiratory tract via the:        

Right Main Stem Bronchus

300

A 6" OID would _______ contrast.

Increase

300

How will x-ray photon intensity be affected if the SID is doubled?

Its intensity decreases four times

300

The normal average rate of respiration for a healthy adult patient is:                

12-20 breaths/min

300

The variation in photon distribution between the anode and cathode ends of the x-ray tube is known as:        

Anode Heel Effect

400

Free air in the abdominal cavity is best demonstrated in which position?

AP projection, left lateral decubitus position

400

The electron cloud within the x-ray tube is the product of a process called:

Thermionic Emission

400

Which interactions between x-ray photons and matter involves a high-energy photon and the ejection of an outer shell electron?        

Compton Scatter

400

In what order should the following examinations be performed on the same patient? 

  1. Upper GI series
  2. IVU
  3. BE

2,3,1

400

The medical term for hives is:

Urticaria

500

Which position would demonstrate the right lumbar zygapophyseal articulations closest to the IR?

RPO

500

Ionization chambers are located between the:

Patient and the IR

500

How many half-value layers will it take to reduce an x-ray beam whose intensity is 78 Gy to an intensity of less than 10 Gy?        

3

500

A condition in which an occluded blood vessel stops blood flow to a portion of the lungs?                

Pulmonary Embolism

500

What is the name of the condition that results in the forward slipping of one vertebra on the one below it?        

Spondylolisthesis