1 GRAM OF THIS IS EQUIVALENT TO SMOKING 6 UNFILTERED CIGARETTES
TISSUE
THIS CONVERSION OCCURS IN THE HAND-PIECE OF HARMONIC DEVICES
ELECTRICAL ENERGY TO MECHANICAL MOTION
THIS ETHICON DEVICE DELIVERS 88% LESS BLEEDING WHEN COMPARED TO THIS COMPETITIVE DEVICE
X1 LARGE JAW OVER LIGASURE IMPACT
IT HAS 3 CUT MODES, 3 COAG MODES AND 2 ADVANCED BI-POLAR MODES
MEGAPOWER
ACE BLADE PROVIDES A SIMILAR EFFECT OF THIS SURGICAL DEVICE
SCALPEL
IT IS KNOWN FOR HAVING THE DESIGN WHERE TRIGGER, OVER THE HAND AND TRADITIONAL GRIP METHODS CAN BE USED
ZIP PEN
THIS ETHICON DEVICE DELIVERS 160% HIGHER BURST PRESSURE RESULTS WHEN COMPARED TO THIS COMPETITIVE DEVICE
HD1000i OVER LIGASURE MARYLAND
ENSEAL ART OFFERS THIS MANY DEGREES OF ARTICULATION
110 DEGREES
THIS DEVICE IS KNOWN AS QUIET, EFFICIENT AND HAS A USER-FRIENDLY DESIGN
MINIVAC
ACE BLADE PRODUCES EQUIVALENT OR SIGNIFICANTLY LESS THERMAL NECROSIS THAN THIS DEVICE
PEAK PLASMA
THIS SMOKE EVACUATOR COMPONENT REMOVES PARTICULATES AND ODORS
CHARCOAL FILTER
WHEN TROUBLESHOOTING HARMONIC, THE BLADE INTEGRITY TEST MUST BE COMPLETED WITH THE BLADES IN THIS POSITION
OPEN
ENSEAL X1 LARGE JAW OFFERS THESE 3 KEY BENEFITS
BETTER HEMOSTASIS, BETTER TISSUE MANAGEMENT AND BETTER DESIGN
THIS DEVICE CAN BE USED TO EVACUATE CO2 PNEUMOPERITONEUM AT THE END OF LAPAROSCOPIC PROCEDURES
MEGAVAC
THE 2 COMPONENTS REQUIRED TO CREATE A GEM (GEOMETRIC ELECTRON MODULATION) EFFECT
ACE MODE AND TAPERED EDGES
SHE IS OUR AORN GO CLEAR AWARD REPRESENTATIVE
HANNAH CAMPBELL
WHAT FEATURE OF HARMONIC IS USED TO OPEN THE JAWS
SPRING ASSIST
IN AN OPEN TLH, THE REDUCED THERMAL FOOTPRINT OF ENSEAL X1 LARGE JAW WOULD BENEFIT A SURGEON WHEN IT COMES TO NOT DAMAGING THIS STRUCTURE
URETERS
THIS FEATURE DESCRIBES THE GEN11’s ABILITY TO SENSE, RESPOND AND DELIVER THE RIGHT AMOUNT OF ENERGY
ADAPTIVE TISSUE TECHNOLOGY (ATT)
ACE BLADE PRODUCED THIS PERCENTAGE LESS HAZARDOUS SURGICAL SMOKE v. STAINLESS STEEL MONOPOLAR ELECTROSURGERY
99.6%
THIS HOSPITAL BECAME SMOKE FREE IN JUST 4 MONTHS AND WAS 1 OUT OF 20 HOSPITALS NATIONALLY THAT WAS AWARDED AORN’S GOLD SMOKE FREE AWARD
HENRY FORD HOSPITAL
THE FREQUENCY OF HD1000i
50,000 CYCLES PER SECOND
THIS IS INHERENT IN ALL ADVANCED BI-POLAR DEVICES, BUT NOT IN ULTRASONIC DEVICES
RADIATED ELECTRICAL ENERGY
OF THE DIFFERENT BI-POLAR MODES ON THE MEGAPOWER GENERATOR, THIS MODE IS DESIGNED TO DELIVER A PRECISE AND CONTROLLED BI-POLAR EFFECT
MICRO
GEOMETRIC ELECTRON MODULATION (GEM) TECHNOLOGY DOES THESE 2 THINGS AS TISSUE IMPEDENCE INCREASES
PROVIDES VARIABLE POWER AND CONSTANT VOLTAGE