EG4
Financiers
Modules
Solar 101
100

How many flexboss21 inverters can you install on a single gridboss? 

100

What does AVL stand for?

Approved Vendor List

100

What makes a bifacial module different than a monofacial?

Bi facial can generate power from the reflection of the roof on the back sheet of the module. 

100

This piece of equipment is responsible for taking DC power and turning it into AC power?

Inverter or microinverter

200

What limitation do the "off grid" inverters have that the hybrid inverters do not?

Off grid cannot send power to utility

200

T/F the end user is not responsible for maintenance on their system if they took out a loan to purchase it. 

False.

200

Will a module in AZ in 92 degree weather produce more electricity than one in FL in 72 degree weather? (assume all other elements are the same) 

No. More heat = less efficient. 

200

What's the most optimal orientation for solar production? 

South

300

What are the breaker sizes you can put inside the Gridboss? 

1 X 125A 

1 X 80A 

2C 60A

300

What's the difference between a prepaid PPA and standard PPA?

Prepaid = one time payment upfront

Standard = monthly payments

300

What is a degradation warranty? 

What % of original nameplate rating the module will still generate after a certain period of time. 

EX: 87% over 25 years. 

300

What is "clipping"?

When DC power is > AC output

Ex: 12kW PV system on a 9kW inverter

400

Which flexboss inverter should you recommend if a customer is installing Solar only (no battery) and the system size is 16kW?

Flexboss21

FB18 would experience clipping. 

400

What's the difference in how the monthly payment is calculated on a PPA vs a loan?

PPA = based on monthly kWh production 

loan = based on system price

400

What does STC rating stand for?

Standard test conditions. 

Basically what the panel can generate under "perfect" conditions

400

What's the difference between a DC coupled battery vs an AC coupled battery?

DC: Power generated from PV goes directly into battery. No inversions

AC: Power generated from PV goes to inverter first first (AC), then to battery where AC is inverted back to DC for charging. 2 inversions = less efficient

500

What is the MPPT DC startup Voltage on the Flexboss21?

200VDC


500

Is the end user still responsible for monthly payments on a standard PPA if the system stops generating power? 

No. PPA monthly payments are based on system kWh production. If there's no kWh production for a month then there's no payment amount. 

500

What does PTC rating stand for?

Performance test rating. More realistic output that you will see in the field. 

500

If a customer is using 2000W of continuous power, how long would it take them to drain a 32kWh battery (assuming 100% DOD)?

16hours

32000W (battery capacity) / 2000W (load)