PPE
Ladders
Fire Extinguishers
Fall Protection
Powered Industrial Trucks (PIT)
100

Does PPE need to be inspected if it appears in good condition?

Yes, regardless of how it appears it needs to be inspected. Sometimes the wear or damage isn't immediately visible

100

The ___________ tag must be present and not damaged

Weight capacity

100

How often must fire extinguishers be inspected? 

Monthly

100

What are some examples of fall protection?

Fall arrest systems, safety net systems, guardrail systems

100

What is an example of a PIT?

Forklift

Narrow Isle Reach

Pallet Jack

Rough Terrain

Counter balance

200

What is the KNCC minimum PPE requirements?

Safety vest or high visibility outerwear

Hard hat

Pants

Workboots

200

How high above the landing must a ladder extend?

3 feet

200

There must be a fire extinguisher every ___________ square feet?

3,000

200

What is the required height of a top rail and mid rail in a guardrail system?

Top rail: 42"

Mid rail: 21"

200

What regulation governs PIT's

29 CFR 1910.178

300

When is a sticker not allowed on your hard hat?

When it is used to conceal damage

300

What types of ladders are considered non-conductive?

Wooden or Fiberglass, although if wood or fiberglass is wet, it will become conductive

300

What are the requirements for placement of a fire extinguisher during the course of construction?

Mounted on a wall or in a stand, off the ground, readily accessible by all workers on site

300

How many pounds should anchors be able to support?

5,000 pounds per employee

300

When should PIT's be inspected?

Before each use, formal inspection done once per shift of use.

400

Which type of hard hat is not intended to provide protection against contact with electrical hazards?

Type 1

Type 2

Class C

Class G

Class E

Type 1: Helmets are intended to reduce the force of impact from a blow only to the top of the head

Type 2: Helmets are intended to reduce the force of impact resulting from a blow to the top or sides of the head

Class C: Helmets not intended to provide protection against contact with electrical hazards (conductive)

Class G: Helmets intended to reduce the danger of contact with low-voltage conductors (proof-tested at 2,200 volts)

Class E: Helmets intended to reduce the danger of contact with higher voltage conductors (proof-tested at 20,000 volts)

400

Where must a ladder be tied off?

Top and bottom

400

How frequent must fire extinguishers get certified?

Annually

400

Can you re-use your harness after sustaining a fall if it appears in good, serviceable condition?

NO! Although it may look good, the harness is to be taken out of service.

400

What is the highest cause of fatalities when it comes to PIT's?

Operator getting crushed from a tip over incident, 42% of fatalities are caused from this.
500

Where does PPE fall in the hierarchy of controls?

Last!

Elimination, Substitution, Engineering, Administrative, PPE

500

What ratio must a ladder be leaned at?

4:1

500

What acronym best describes how to use a fire extinguisher?

PASS: 

Pull

Aim

Squeeze

Sweep

500

OSHA requires fall protection for employees are exposed to a hazard of falling ________ feet or more?

6 feet

500

The ___________ will protect the operator from small boxes and package but not everything

Overhead guard