Does PPE need to be inspected if it appears in good condition?
Yes, regardless of how it appears it needs to be inspected. Sometimes the wear or damage isn't immediately visible
The ___________ tag must be present and not damaged
Weight capacity
How often must fire extinguishers be inspected?
Monthly
What are some examples of fall protection?
Fall arrest systems, safety net systems, guardrail systems
What is an example of a PIT?
Forklift
Narrow Isle Reach
Pallet Jack
Rough Terrain
Counter balance
What is the KNCC minimum PPE requirements?
Safety vest or high visibility outerwear
Hard hat
Pants
Workboots
How high above the landing must a ladder extend?
3 feet
There must be a fire extinguisher every ___________ square feet?
3,000
What is the required height of a top rail and mid rail in a guardrail system?
Top rail: 42"
Mid rail: 21"
What regulation governs PIT's
29 CFR 1910.178
When is a sticker not allowed on your hard hat?
When it is used to conceal damage
What types of ladders are considered non-conductive?
Wooden or Fiberglass, although if wood or fiberglass is wet, it will become conductive
What are the requirements for placement of a fire extinguisher during the course of construction?
Mounted on a wall or in a stand, off the ground, readily accessible by all workers on site
How many pounds should anchors be able to support?
5,000 pounds per employee
When should PIT's be inspected?
Before each use, formal inspection done once per shift of use.
Which type of hard hat is not intended to provide protection against contact with electrical hazards?
Type 1
Type 2
Class C
Class G
Class E
Type 1: Helmets are intended to reduce the force of impact from a blow only to the top of the head
Type 2: Helmets are intended to reduce the force of impact resulting from a blow to the top or sides of the head
Class C: Helmets not intended to provide protection against contact with electrical hazards (conductive)
Class G: Helmets intended to reduce the danger of contact with low-voltage conductors (proof-tested at 2,200 volts)
Class E: Helmets intended to reduce the danger of contact with higher voltage conductors (proof-tested at 20,000 volts)
Where must a ladder be tied off?
Top and bottom
How frequent must fire extinguishers get certified?
Annually
Can you re-use your harness after sustaining a fall if it appears in good, serviceable condition?
NO! Although it may look good, the harness is to be taken out of service.
What is the highest cause of fatalities when it comes to PIT's?
Where does PPE fall in the hierarchy of controls?
Last!
Elimination, Substitution, Engineering, Administrative, PPE
What ratio must a ladder be leaned at?
4:1
What acronym best describes how to use a fire extinguisher?
PASS:
Pull
Aim
Squeeze
Sweep
OSHA requires fall protection for employees are exposed to a hazard of falling ________ feet or more?
6 feet
The ___________ will protect the operator from small boxes and package but not everything
Overhead guard