General 1
Electrical 1
General 2
Electrical 2
Potpourri
100
This is who can only ride on a tractor, bulldozer, forklift, unless specifically authorized by management.
Who is the OPERATOR? G4.28
100
______ and sleeves shall not be stored in a folded or creased position.
What are BLANKETS? E1.07
100
This can be done to a ladder to help ensure the stability of the ladder.
What is tying off the ladder or having a co-worker foot the ladder? G4.37
100
Persons who are not operating excavation equipment such as backhoes, trenchers, ect. shall not ______ the excavation equipment while digging.
What is CONTACT? E1.19
100
Only these climbing devices in good operating condition and of approved size for the job shall be used.
What are ladders? G4.34
200
These shall be used to protect fellow workers from direct rays of electric arc or welding flame.
What are safety signs, shields, or barricades? G5.04
200
These shall be worn while workers are climbing poles with equipment energized at any voltage from ground to ground.
What are class O PIPE? E2.04
200
These shall be operated per manufacturer's guidance and in accordance with AEP manlift training.
What are MANLIFTS? G5.19
200
All ____ _____ equipment shall be of an approved material, carefully inspected, properly stored, and cared for.
What is INSULATED PROTECTIVE ? E1.06
200
When raising or lowering poles in close proximity to energized conductors, these conductors shall be prevented from making _______ contact with the pole by using guards or IPE.
What is ELECTRICAL? E2.21
300
_____ ______ tools shall be used where there is a danger of accumulated hydrogen. (batteries)
What is SPARK PROOF? G6.04
300
You must have _____ feet of insulation of a live-line tool for 138kv.
What is 4 FEET? E2.09
300
This shall be obtained before a welding or cutting operation in a area where there could be a fire hazard.
What is a HOT PERMIT/ PROPER AUTHORIZATION? G5.07
300
No work shall be done on ______ and ______ where a dispatcher authority is required.
What are LINES and EQUIPMENT? E 2.34
300
These devices that are connected to primary voltages through capacitors or resistors are not required to be isolated within a clearance zone.
What is POTENTIAL DEVICES? Site.A3a
400
These are used to prevent the ionized air or metalic vapor causing a flashover when welding.
What are SOLID PROTECTIVE BARRIERS? G5.06
400
When conductors being installed/ removed cross over energized conductors over 600 volts, the ______ ______ feature of the circuit devices shall be made inoperative.
What is AUTOMATIC RECLOSING? E2.31
400
This is what employees shall use before operating or working on any line or equipment, per applicable policy.
What is use the proper clearance procedure? G1.25
400
Energized cables, which are to be moved, rated over _____ volts shall not be bent or re-racked while energized.
What is 600 VOLTS? E3.03
400
When working on underground parts energized greater than _____kv where contact may be made, workers shall wear PIPE and stand on insulated rubber mat, blanket, or platform.
What is 1 KV ? E2.42
500
All handling, storage, transportation and use of chlorine/ anhydrous ammonia shall be in accordance with the AEP ______ and ______ ______ use policies.
What is CHLORINE and ANHYDROUS AMMONIA? G6.08
500
A crew can isolate a line not under the control of a dispatcher by an appropriate sitching device. Name Three
What is an automatic breaker, recloser,sectionalizer, switch, or fuse? E2.36
500
This which is a byprodect of burning eastern bituminous coal may be deposited in internals of steam generators and ductwork in power plants.
What is ARSENIC? G6.10
500
Name two conductor support tools that may be used to provide clear insulation as long as the insulator string.
What are LINK STICK,STRAIN CARRIERS, INSULATOR CRADLES? E2.13
500
Where a cable in a manhole has abnormalities that could lead to an impending fault, the defective cable shall be _____ before an employee may work in that manhole.
What is DE-ENERGIZED? E3.04