Scatter Basics
Collimator
Grids
Air Gap & Shielding
Restricting Devices
100

Scatter Radiation is the primary result of THIS interaction.

What is Compton Interaction?

100

Collimation is also referred to as THIS.

What is Beam Restriction?

100

THIS is the Intended Purpose of Radiographic Grids.

What is Absorbing Scatter Radiation from the Patient?

100

A lead shield is placed on the X-ray table in front of the patient to reduce THIS.

What is Scatter Radiation that Reduces Image Quality?

100

THIS is Considered to be the Best Beam-Restricting Device available in Radiography.

What is a Collimator?

200

The probably of Compton Scattering is directly related to THIS.

What is the Energy of the Photon?

200

A collimator has THIS many sets of lead shutters.

What is Two - Three?

200

THIS contains a Permanently Mounted Grid & allows the IR to Slide Behind it.

What is a Grid Cap?

200

THIS is the Important Step that Affects the Processing of the Digital Image.

What is Accurate Placement of the Lead Shield?

200

THIS is the Simplest Beam-Restricting Device, consisting of a Flat Piece of Lead with a Hole in it.

What is the Aperture Diaphragm?

300

THIS makes scatter radiation detrimental to radiographic quality.

What is Unwanted Exposure (Fog)?

300

THIS type of collimator automatically limits the Size and Shape of the Primary Beam to the IR.

What is the Automatic Collimator?

300

THIS is the range of dimensions for a Lead Grid Device.

What is 8x10 in. - 17x17 in. & Approx. 1/4 in. thick?

300

THIS Simple Concept states that the Greater the Gap, the Greater Reduction in Scatter Radiation Absorbed by the IR.

What is the Air Gap Technique?

300

THESE Devices limit the Degree of Unsharpness surrounding the Radiographic Image.

What are Cones and Cylinders?

400

THESE two major factors affect the amount of scatter radiation produced.

What is Tissue Volume & kVp (Kilovotage Peak)?

400

The collimator includes a White Light Source, which highlights THIS in the Patient Light Field.

What is the Exposure Area of the Primary X-Ray Beam?

400

THIS is the Formula to calculate the Grid Conversion Factor.

What is GCF = mAs with the Grid / mAs without the Grid?

400

THESE help to limit Occupational Scatter Radiation Exposure from a Patient.

What are Lead Aprons and Appropriate Distance from the X-Ray Field?

400

THESE are disadvantages Cones and Cylinders have against Aperture Diaphragms.

What is Limited Sizing and Inability to be Swapped Out (Not Interchangeable)?

500

THESE are tools that Radiographers use to limit the affects of scatter radiation on the radiographic image.

What are Beam-Restricting Devices & Radiographic Grids?

500

The collimator is equip with THIS as a fail-safe if failure of the White Light Source and Mirror occurs.

What is the X-Ray Field Measurement Guide?

500

THIS is the Direct Relationship that improves Scatter Clean-up.

What is an Increase in Grid Ratio & Radiographic Contrast. ?

500

THIS is the most common application of the Air Gap Technique due to the Limited Proximity to the Patient's Spine.

What is Lateral Projection of the Cervical Spine?

500

THIS helps a Radiographer Reduce Unnecessary Radiation Exposure by making it Difficult to Increase the Primary Beam Field to larger than the IR.

What is an Automatic Collimator?