Things you use
I liked them way back, you know when they were underground (Underground Drop)
Color Me Badd (811 Locate Colors)
Anatomy of Cable
ANSI glad I didnt say banana? (ANSI/OSHA)
100

Active devices used to offset losses of long drops and splitters within the interior drop system.

House Amplifiers

100

This is how many splices are permissible in a drop that is greater than 60', with or without a driveway between the pedestal and the house.

2

100

Purple

Reclaimed Water, Irrigation, and Slurry Lines

100

The characteristic of RF propagation in a cable in which the higher frequencies tend to travel along the surface of the conductor rather than throughout its mass.

Skin Effect:

100

Specification for Braided 75 Ω Flexible RF Coaxial Drop Cable,

ANSI/SCTE 74 2011

200

Connects devices in the customer’s home or business to the Distribution.

Drop Cable

200

Drops that are less than 150ft in length should be this type of cable

RG-6

200

PINK

Temporary Survey Markings
200

The insulating material separating two conductors, such as that between the center conductor and sheath in a coaxial cable.

Dielectric

200

Vehicle Mounted Elevating and Rotating Work Platforms

ANSI A92.2

300

Includes set-top boxes, DTAs (Digital Terminal Adapters), cable modems, eMTAs, PCs, home theater systems, game systems, telephones, and home security devices.

Customer Premises Equipment (CPE)

300

 A right to use another person's real estate for a specific purpose.

Easement

300

WHITE

Proposed Construction/ Excavation

300

Passage of signal intended to remain within the cable into the outside world can result in a weaker signal at the end of the cable and radio frequency interference to nearby devices.

Egress

300

OSHA Regulation for Confined Spaces

1910.146

400

Provides the means to bond the drop cable to the house common electrode system.

Bond Block

400

Underground drop cables routed down a pole must have physical protection, cable guard, or conduit to a point at least_____feet above ground and to at least____ inches below ground.

8, 8

400

YELLOW

Gas-Oil-Steam

400

Passage of an outside signal into the cable can result in noise and disruption of the desired signal.

Ingress

400

F-81 Barrel connectors all need to meet the minimum requirements of 

ANSI/SCTE 01 2015

500

A mechanical device that is fitted onto the coax to allow connection to the tap, etc.

F-connector

500

Rg-11 or QR 320 should be used for drops that do next exceed how many feet

300ft

500

BLUE

WATER
500

This type of cable is jacketed with a fire-retardant plastic jacket. Because it is part of the air distribution system, cables installed in this space require a higher fire rating.

Plenum

500

all cable for RF distribution must meet all the minimum specifications for

ANSI/SCTE 74 2011