Don't you love Statistics?
OMG, more Statistics?
Dosimetry
More Dosimetry
Instrumentation
100

These tests verify that the equipment is still operating within an expected range of response and enable us to track performance while in use. 

Quality Control

100

This is the smallest amount of activity that can be detected at a 95% confidence level.

MDA or Minimum Detectable Activity

100

Absorbed dose is expressed in terms of this

The rad

100

To exceed the limiting values set forth in 10 CFR 835 is to ____ __ ___

Violate the law

100

The RO-20 is a radiation detector used at PORTS that operates within which region on the Gas Amp Curve?

Ion Chamber

200

This is the radiation that enters the detector concurrently with the radiation being analyzed

Background

200

Maintaining these little metal circles in a clean manner increases reliability of counting equipment.

Planchets

200

This is the quantity of a single radionuclide that if inhaled or ingested in one year would irradiate a person to the limiting value of 5 rems

ALI

200

The federal dose limit for a radiological worker to the whole body is ___ rem/year

5

200

The Lud 12S that was used when the RCT surveyed Sanitary Trash is which kind of detector?

Scintillation or Excitation

300

Because we prefer to be right more than wrong, counting results are reported in a range that would be correct 95% of the time or at a 95% _____ ____

Confidence level

300

This is the level at which there is a 5% chance of calling a background level "greater than background"

Critical Detection Level

300

This is the science of dealing with the evaluation of the equivalent dose resulting from energy deposited within the body by radiation. 

External Dosimetry
300

The federal dose limit for a declared pregnant worker is ___ rem per gestation period

0.5

300

What is the correction factor for Removable for the Lud 12 alpha (43-5)?

2

400

This format used when reporting uncertainty

x.xx ± yy

400

This phenomenon occurs on proportional counting systems when an alpha generated pulse is not large enough to exceed the upper discriminator and is counted as a beta.

Crosstalk

400

This is the analysis and measurement of intakes and doses from radionuclides in the human body. 

Internal Dosimetry

400

Federal dose limits for minors and members of the public are ___ rem per year

.1

400

What is the beta correction factor for the Lud 2360?

8

500

By doing this, we can reduce uncertainty and improve statistical validity of samples.

Increase background count time

500

Which two counting systems used at PORTS contain discriminator settings to address Crosstalk?

3030 and Tennelec

500

Which type of bioassay measurement deals with urine and fecal collections?

In-Vitro

500

The administrative control level for a radiological worker at PORTS is _____ __ per year

500 mrem

500

Which semi-portable scintillation instrument used at PORTS uses Pulse Height Analysis?

3030