Reprocessing Basics
Products & Chemicals
Instrument
Classification
Quality Assurance
Packaging & Sterilization
100

The process that makes reusable medical devices safe for patient use through cleaning, disinfection, and sterilization.

What is reprocessing?

100

These products are used on living tissue to reduce microorganisms.

What are antiseptics?

100

Equipment is classified using this system.

 What is Spaulding Classification?

100

These indicators answer the question, "Was it exposed?

What are chemical indicators?

100

Only this number of instruments should be placed in each self-sealing pouch.

What is one instrument per pouch?

200

This step removes organic material such as blood, mucus, and tissue debris.

What is cleaning?

200

These products are used on non-living surfaces to eliminate microorganisms.

What are disinfectants?

200

 Instruments that enter sterile tissue or the uterine cavity belong to this category.

What is Critical equipment?

200

These indicators are considered the gold standard for monitoring sterilization effectiveness.

What are biological indicators?

200

When labeling sterilization pouches, these three pieces of information must be included.

What are the date, initials, and load number?

300

This is the primary goal of instrument reprocessing.

What is preventing the spread of infection and ensuring patient safety?

300

This enzymatic cleaner is used in our clinics to remove organic debris.

What is Empower?

300

A vaginal speculum falls into this classification.

What is Semi-Critical equipment?

300

Internal and external indicators are examples of this type of indicator.

What are chemical indicators?

300

Packages should be loaded in the autoclave this way to allow steam circulation and effective sterilization.

What is without touching or overlapping?

400

The recommended workflow direction in a reprocessing area.

 What is dirty-to-clean workflow?

400

Empower should be prepared using this amount of solution per gallon of water.

What is 30 mL per 1 gallon?

400

A blood pressure cuff is classified as this.

What is Non-Critical equipment?

400

Chemical indicators change this when sterilization conditions are reached.

What is colour (or appearance)?

400

This type of water should be used in the autoclave.

What is distilled water?

500

The correct order of the main reprocessing steps.

What are pre-cleaning, transport, cleaning, disinfection (if applicable), packaging, sterilization/autoclaving, and storage?

500

Instruments should be placed into Empower as soon as possible after use to prevent this.

What is debris drying onto the instrument?

500

This body site is considered sterile and makes many IUD instruments critical devices.

What is the uterine cavity?

500

Biological indicators use these resistant organisms to verify sterilization.

What are bacterial spores?

500

After sterilization, packages with this condition are no longer considered sterile and must be reprocessed.

What are wet packs?