Steam 1
Steam 2
Steam 3
Hydronics 1
Hydronics 2
100

These pumps cannot be started with the discharge valve closed and must be equipped with a relief valve on the discharge line to protect the pump from excessive pressure.

What are Rotary Feedwater Pumps.

100

The advantages are withstanding pressures up to 2,700 psi and a capacity of 20,000 lb/hr

What is an inverted bucket steam trap

100

Required fall in the direction of flow for a "clean" steam system

What is 1":10'

100

Number of distinct cycles in a hydronic cooling cycle

What is 5

100

Flashing of pumped liquid into vapor bubbles and their subsequent violent collapse from the suction side to discharge side of a pump

What is cavitation

200

What is the critical dimension in a one-pipe counter flow system for the return riser and the Hartford Loop?

What is the "A" dimension.

200

Vapor steam heating systems create the vacuum condition by preventing the admittance of air at this time

What is in the "off" cycle

200

Two options to conduct hydrostatic testing

What is remove safety valve and install blinds or gag the safety valve.
200
Most common methods of sealing centrifugal pumps

What is stuffing box seal and mechanical seal

200

Maximum of two circuits

What is a single loop system

300

The two basic parts of a steam system

What are the Boiler and the HTU's.

300

Required pitch for two pipe steam system

What is 1/2" per 20'

300

Radiation, conduction, and convection require this for heat transfer to occur

What is a medium between two objects.

300

Most important method of heat loss to control to achieve a comfort condition

What is radiation

300

R-value measures

What is thermal resistance of a material
400
Superheated Steam condition

What is no contact with water

400

Organization overseeing laws, rules, and regulations relating to boilers

What is the NBBI (National Board)

400

Two methods of bringing condensate back to a boiler in a one-pipe system

What is parallel flow or counter flow

400

Temperature is an indirect measure of what

What is the velocity of molecules

400

Most common inputs on a hydronic system

What are temperature sensors
500

Where the vacuum exists on a variable vacuum steam system

What are the steam supply and the condensate return

500

Where water is pumped from during an emergency shutdown in a boiling water reactor

What is the Torus

500

Typically suspended from the ceiling to be used as a space heater`

What is a unit heater

500

The point of highest temperature determines what

What is the location for air separators.

500

Weight of HTF vertically relative to the pump

What is static head