It's the TXV
Brett Says....
Rob Says...
Got no Gas in it (leaks and repairs)
Systems that don't Quack (ductless)
100

The TXV’s main job is to control the flow of refrigerant into this component

What is the evaporator coil

100

The evaporator coil in a refrigerant system is where this happens to the refrigerant

What is refrigerant boils and absorbs heat

100

What two types of questions do we use to gather information from the customer

What are open-ended and closed-ended questions

100

This gas is used while brazing to prevent scale and oxidation inside copper lines

What is nitrogen

100

This board is the “brain” of the Mini split, controlling fans, sensors, and compressor speed.

What is the printed circuit board (PCB)

200

If a TXV is restricted or stuck closed, this pressure reading will be lower than normal

What is the suction pressure

200

This term describes the heat required to change a substance from liquid to gas without changing temperature.

What is latent heat

200

This is the first step of the Service System

What is Prepare

200

The factory charge is typically based on this length of refrigerant lines.

What is 15 feet (or manufacturer-specified base line length)

200

This component meters refrigerant electronically instead of using a pressure/temperature spring system.

What is an electronic expansion valve (EEV, TEV)

300

If a TXV is stuck open, what would our Superheat be?

low superheat

300

A ton of refrigeration equals how many BTUs per 24 hours

What is 288,000 BTU

300

This DISC style prefers a methodical, accuracy-based approach

What is the C style

300

When pulling a vacuum, the system is considered dry when it reaches this threshold or lower.

What is 500 microns

300

This sensor changes resistance based on temperature and helps the Mini split regulate room conditions.

What is a thermistor

400

Name the 3 pressures that the TXV works off of

What is Spring, suction, and Sensing Bulb pressure

400

A high superheat and low subcooling reading indicates this about the refrigerant charge

What is the system is undercharged (starved)

400

Name all 6 steps of the Service System in order.

What are Prepare, Greet, Explore, Present, Execute, Wrap Up

400

: This component may be replaced during a refrigerant leak repair to ensure the system stays dry and clean

What is the filter drier

400

Inverter compressors operate using this type of voltage.

What is DC Voltage

500

What is the Superheat formula for a Piston?

IWBx3-80-ODA/2

500

This DISC style is most likely to be resistant to sudden changes and values steadiness

What is the S style

500

This procedure removes air, moisture, and non-condensable from a sealed system

What is pulling a vacuum

500

The EEV often operates using this type of motor, which moves the valve in precise steps

What is a stepper motor