100

What is it called when supply hose beds on apparatus are divided into two or more suctions

What is a split hose bed

100

list the three supply hose lays

What is, Forward, reverse, and split

100

in the hose bed, where does the male end of a supply line go for a flat lay? 

the front

100

why do you roll the hose before loading it onto the hose bed

to get the air our

100

what are the three basic supply line hose loads

flat, accordion, and horseshoe. 

200

what type of suction hose is used to draft water from a dry barrel hydrant

what is soft sleeve

200

a working hose drag can be used to transport supply lines over..

what is relatively short distance

200

a shoulder carry is practical when?

what is, to transport full lengths of hose in a longer distance. 

200

what are the two types of standpipe systems?

what is, dry and wet

200

preconnected typically have how much hose

what is, 150 to 250 feet. 
300

what is the purpose of a four-way hydrant valve

what is, it is used for long supply lines that need more pressure to flow water. 

300

what is the recommended PSI for a sprinkler system

what is, 150 PSI

300

what load allows a single firefighter is able to flake out one fold or loop of hose at a time from the shoulder toward the fire

what is, minuteman hose load

300

a burst hose line should be shut down and replaced with what

2 sections of hose 

300

what hose load has the male end starting in the lower left corner of the hose bed and the female is ending in the middle

horseshoe load

400

connecting to a standpipe system can help supply what in a building?

what is, sprinkler systems/standpipe

400

firefighters can add an extra hose to the discharge end of the attack line with what

break away type nozzle

400

when flaking out a hose to a standpipe what direction should the hose be flaked

flake the hose up the stairs to the fire floor, above the fire floor, or along a hallway outside the fire compartment

400

why should a horseshoe and an accordion load not be used for supply lines

they tend to fall on themselves and damage the edges of the hose

400

where is the transverse side of the engine located

over the pump panel

500

what type of load is suited for one to two-story dwellings

what is, triple layer hose load
500

a wye requires one supply line to make two attack lines, what are the three lines required to make this work

what is, 1 2 1/2 and 2 1 3/4

500

In a siamese adaptor what valves eliminate the risk of backflow of water to the engine

clapper valve

500

List the 5 examples of friction points FROM THE BOOK

what is, changing directions, turning a corner, going through a doorway, going up and down stairs

500

When advancing an attack line up a ladder, a second fireman should grab the hose every 

what is, 25 feet