pH
Metal Detection
Allergens
Swabs/Sanitation
CoAs
100

The name of the document detailing all things pH related

pH Meter Calibration and Operation

100

The amount of times QA should verify the functionality of a metal detector

Minimum of 4 per shift

100

The Big 9 Allergens

Egg, Milk, Fish, Shellfish, Peanut, Tree Nut, Soy, Sesame, Wheat

100

The amount of space you are supposed to swab for a Microbial Swab

4 x 4 inch

100

The TA% specification for Buttermilk

0.43-0.57

200

The acceptable range for the slope of the pH meter calibration

92-102%

200

The two types of metal detectors we utilize

In-Line (pipeline) and On-Line (tunnel)

200

Test we use to validate allergen cleaning practices (FULL NAME)

Enzyme-Linked Immunosorbent Assay

200

The number of different color brushes we have in our color brush program

6 (black, red, green, blue, white, yellow)

200

The Brix Specification for Corn Syrup

81.4-84.6

300

The document number associated with all things pH related

9.1

300

The 4 types of metal standards that utilize

1.5mm FE, 2.0mm Non-FE, 2.5mm 316SS, 3.0mm 316SS

300

The document number for the Allergen Program

2.3.0.0

300

The 5 Steps in a typical CIP

1. Pre-Rinse

2. Caustic Wash

3. Rinse

4. Sanitize

5. Rinse

300

CoA Verification Document Number

7.02

400

The formula that we currently make with the highest pH specification

AU066 (4.00-4.50)

400

The document number detailing the metal detector procedure

11.4.02

400

The FDA recently removed this food from being classified as a tree nut

Coconut

400

The 3 types of Sanitizer we use and where they are used.

PentaSan - Bulk and TF CIP

Oxywave - Central Dispensing System

Madisan 75 - Chemical Room Dispenser

400

The 3 specific pathogens tested for on an Egg CoA

Listeria, Salmonella, E. Coli

500

The name of the document where you record pH calibration results

Lab Instrument Calibration and Audit Log

500

The duration of time that 3 successive detection and rejection events must be completed in (according to Operations Paperwork)

10 Seconds

500

The document number for the liquid swab results.

QA Form 36

500

The name of the reaction occurring in the Luminometer during ATP Swabs

Luciferin Reaction

500

The 4 things QA and Receiving Personnel should verify as stated in the Bulk Ingredient Receiving Program

1. Tamper evident Seals (intact and correct #)

2. Unloading ports clean

3. Hoses and Pipes clean

4. Valid CoA