10.15
Miscellaneous
100
The seat on public toilets
What is open front
100
PEX horizontal
What is 32"
100
The lowest horizontal piping of a drainage system that extends from the base of the main stack to a terminating point ten ft outside the inner surface of the foundation wall
What is Building drain
100
Waste discharged from toilets or urinals
What is Black-water
100
when color marking is employed, potable water shall be painted
What is green
200
A floor drain outlet pipe shall not be less than
What is 2 inches
200
4" ABS horizontal
What is 4 ft
200
The pipe that begins 10' outside the inner face of a building's foundation wall
What is Building Sewer
200
A kitchen sink shall connect ____________ to the sanitary drainage system
What is independently
200
exterior drainage pipe for conveying storm water
What is leader
300
The water supply to a shower head shall be supplied through this type of product-approved individual valve
What is thermostatic, pressure balancing
300
3/4" black iron for gas
What is 8 ft
300
A water supply pipe which extends vertically one full story or more
What is Riser
300
DFU rating for bathroom group consisting of tank type w/c, lav, bathtub or shower
What is 6
300
A passive interceptor whose rated flow is 50 gpm or less
What is Grease trap
400
The stand pipe for a domestic washing machine shall extend to a minimum of 30 inches above what
What is the base of the machine
400
1 1/2" Stainless Steel Tubing horizontal
What is 10 feet
400
A tank or pit below normal grade that receives sewage or liquid waste
What is sump
400
Minimum discharge capacity of a sewage ejector
What is 20 gallons per min.
400
Vents serving hazardous waste piping shall not
What is to vents serving the the sanitary drainage system
500
An additional one of these must be installed in preparation rooms at funeral establishments on the water distribution system to the building at the outlet side of the meter or main control valve
What is reduced pressure zone backflow preventer
500
1 1/4" CPVC horizontal
What is 4 ft
500
The portion of a drainage system that cannot drain its discharge into a building sewer via the force of gravity
What is Building Subdrain
500
The waste discharge pipe from an individual fixture pump shall have this
What is a check valve
500
A plumbing system installed prior to March 11, 2005
What is Existing Work