Gas Furnaces
Oil Furnaces
Hydronics
Heat Pumps
Electrical
100

This measurement is commonly abbreviated BTU.

What is a British Thermal Unit?

100

A nozzle's minimum operating pressure.

What is 100 PSI?

100

Most hydronic expansion tanks come pre-charged at this PSI.

What is 12 PSI?

100

During the defrost cycle, the heat pump switches to this mode.

What is cooling?

100
The measurements in which capacitors are rated.

What are microfarads and volts?

200

The correct manifold pressure for a single stage, propane gas furnace.

What is 10 to 11 inches water column?

200

The maximum Ohms for flame signal on a burner.

What is 1,500 to 1,600 Ohms?

200

The weight of 1 gallon of water at 60 degrees Fahrenheit. 

What is 8.33 pounds?

200

In heating mode, the outdoor coil functions as this.

What is an evaporator?

200

The amount of current a #10AWG wire can handle.

What is 30 amps?

300

The average BTU content per cubic foot of natural gas in our area.

What is 1,040 BTU/ft3?

300

The output voltage range of a solid state igniter.

What is 14,000 to 20,000 volts?

300

The height that water will be raised if 1 PSI of pressure is applied.

What is 2.31 feet?

300

What the large center pipe of a reversing valve is considered.

What is the true suction line?

300

The frequency at which electrical equipment in the USA is rated in.

What are 60 Hertz?

400

When checking polarity of a gas furnace transformer, this is the proper voltage between L1 and R on the control board.

What is approximately 96VAC?

400

When measuring resistance of a solid state ignition transformer, these should be the readings from post to post and from each post to ground.

What are 1,300 to 1,500 Ohms from post to post and half of that reading from each post to ground?

400

The number of BTU's a 3/4" copper pipe can carry.

What is 40,000 BTU's?

400

The type of liquid line filter drier used on a heat pump system.

What is a bi-flow?

400

This many BTU's is equal to 1 kilowatt.

What is 3,412 BTU's?

500

This formula is used to calculate CFM.

What is CFM = BTU output/(1.08*ΔT)?

500

The number of BTU's per gallon of #2 Fuel Oil.

What is 139,600 BTU's?

500

The pressure a system should be at if the highest point is 35 feet.

What is 18.15 PSI?

(35 feet/2.31 feet per PSI + 3 PSI)

500

Degrees above ambient temperature that the compressor discharge line temperature should be.

What is 100 to 110 degrees Fahrenheit?

500

The minimum wire size needed for a condensing unit with a rating of '21 Amp Minimum Circuit Ampacity, 50 Amp Maximum Over Current Protection'.

What is #10AWG?