Water Supply and Distribution
Sanitary Systems
Refrigeration and A/C Systems
Heating Systems
Air Handling and Distribution Systems
100

This is the temperature and psi that chlorinated polyvinyl chloride (CPVC) piping can withstand when used for interior water distribution.

What is 180 degrees Fahrenheit and 100 pounds per square inch?

100

This is one advantage of using plastic pipe in sanitary systems.

What is low-friction resistance?

100

This type of evaporator is designed to directly cool the air in a conditioned space by air circulation over it to the refrigerant inside the tubing.

What is Air-cooling Evaporator?

100

This is the types of heat transfers.

What is conduction, convection, and radiation?

100

These are the rating classifications for fire dampers.

What is A, B, or C?

200

This is the amount of threads that can be exposed after connection is tight when pipe is screwed on. 

What is no more than 3?

200

This is the type of test(s) used in sanitary systems.

What is 

Air Test

Water Test 

Final Test?

200

This type of control is used to control the equipment that maintains a predetermined humidity of the space where it is installed.

What is humidistat?

200

This type of warm-air heating equipment includes elements of gravity warm-air system plus a fan to ensure adequate air distribution.

What is Forced-Air System?

200

These are the three common dampers.

What is Multiple-blade, Butterfly, and Split damper?

300

This is the minimum clearance(s) for sprinkler systems. 

What is 3 feet in front of all equipment and 6 inches behind the equipment?

300

This is the distance that water service and sewer lines will be separated by undisturbed or compacted soil.

What is 5 feet?

300

Prior to testing the refrigeration system, you should check gauges used to complete the test and verify that the equipment has been pre-tested and what other item. 

What is certified?

300

This is the minimum distance a furnace should be installed from combustible material. 

What is 18 inches?

300

This is the amount of days you have to notify the contracting officer of any deficiencies encountered when testing, adjusting and balancing.

What is 3 days?

400

This is the Americans with Disabilities Act (ADA) compliant for drinking fountains or water coolers. 

What is a minimum of 30 to 48 inches of clear floor space?

400

This is the type of trap used to prevent grease, oil, sand, or any other undesirable item from entering the sewer system.

What is interceptor?

400

This type of compressor is used in large refrigerating and air conditioning systems to handle large volumes of refrigerants at low pressure differentials.

What is centrifugal? 

400

This type of warm-air heating equipment is used for heating rooms and similarly enclosed spaces, either in addition to, or in place of, a central heating system. 

What is Space Heater?

400

This is the mechanical fastener spacing when inspecting rectangular- shaped exposed ducts.

What is less than 12 inches apart and not more than 3 inches from the edges of insulation joints?

500

This is the temperature you should check at the beginning and the end of the test for temperature differential when testing waterlines. 

What is ambient temperature?

500

These are the different types of sanitary pumps.

What is 

Rotary Pump

Reciprocating Pump

Centrifugal Pump?

500

This type of air conditioning unit is complete with a compressor, condenser, evaporator, controls, and casing.

What is self-contrained?

500

This type of heat transfer is the transfer of heat by means of mediums, such as water, air, and steam.

What is Convection?

500

These are the activities you must check when balancing and testing, Verify that all bearings are adequately lubricated, Check tension on all belts and the adjustment of fan pulleys and what other item.

What is 

Confirm that temporary filters are installed for testing purposes?