Which of the following is NOT a standard size breaker?
A. 110
B. 90
C. 350
D. 75
D. 75
TABLE 240.6(A)
The number of bends in a run of PVC between pull points shall not exceed ____ Degrees
360
352.26
Insulated conductors enclosed within an overall nonmetallic jacket.
Type NM
334.2
Your customer is converting from an electric range to gas and needs a 120v receptacle for the new range. Can you add the receptacle from the existing kitchen counter receptacles?
Yes
210.52(B)(2) Exception 2
A location that does NOT require AFCI protection for 120v, 15 or 20 amp circuits in a Dwelling unit.
Bathrooms
Outdoors
Garages
Attics
Basements/crawlspaces
210.12(A)
Appliance receptacle outlets installed in a dwelling unit for specific appliances, such as laundry equipment, shall be installed within ______ of the intended location of the appliance.
6ft
210.50(C)
Any switch or device that is normally used to start and stop a motor by making and breaking the motor circuit current.
Controller
430.2
You run a 12/3 circuit to a shed for some lighting and receptacles. Does the shed require a grounding system?
No
250.32(A) Exception
The situation(s) that do NOT allow type MC cable installed
330.12
Where subject to physical damage
Where exposed to any of the destructive corrosive conditions in (a) or (b), unless the metallic sheath or armor is resistant to the conditions or is protected by material resistant to the conditions:
Direct buried in the earth or embedded in concrete unless identified for direct burial
Exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids
Type UF shall be permitted to be installed embedded in poured concrete or cement. True or False?
False
340.12(8)
Areas where pool sanitation chemicals are stored, handled, or dispensed, and confined areas under decks adjacent to such areas, as well as areas with circulation pumps, automatic chlorinators, filters, open areas under decks adjacent to or abutting the pool structure, and similar locations.
Corrosive Environment.
680.2
An intersystem bonding termination is not required where _____
communications systems are not likely to be used.
250.94 Exception to A and B
The type of lighting NOT allowed in a clothes closet
Incandescent luminaires with open or partially enclosed lamps and pendant luminaires or lampholders
410.16(B)
The degree column that shall be used for Type NM ampacity
60 degree
334.80
Those systems intended to supply power to public or private facilities or property where life safety does not depend on the performance of the system. These systems are intended to supply on-site generated or stored power to selected loads either automatically or manually.
Optional Standby Systems
702.2
When does a neutral conductor Not have to be identified or grouped with its corresponding ungrounded conductor with cable ties or similar?
if the branch-circuit or feeder conductors enter from a cable or a raceway unique to the circuit that makes the grouping obvious
200.4(B) Exception 1
The following wire method that is NOT acceptable as an Equipment Ground
A. Flexible metal conduit with a circuit rated 30Amps
B. Liquid Tight FMC with a circuit rated 60Amps
C. Flexible metallic tubing not exceeding 6'
D. A copper-clad aluminum, stranded, insulated conductor
A. Flexible metal conduit with a circuit rated 30Amps
250.118
Seal Tight Connectors are permitted to be installed underground. True or False?
Angle connectors are NOT permitted for direct burial.
Straight connectors are permitted for direct burial.
356.42
Any space of a health care facility wherein patients are intended to be examined or treated
Patient Care Space
517.2
A customer wants a receptacle installed for a bidet and the toilet is directly next to the tub. Can you install this compliant with the NEC?
Yes
406.9(C) Exception 2