The alternative replacement breaker for a Siemens
What is an Eaton CL?
The smallest kitchen counter space required to have a receptacle installed.
12 inches
210.52(C)(1)
Is this a standard size breaker according to the NEC
No
Table 240.6(A)
A separate building does not require a grounding system when _______.
250.32(A) Exception
Note: this exception does not apply to a Feeder.
Read definitions of feeder and branch circuit
What’s an electrician’s favorite ice cream flavor?
Shock-o-late
The alternative replacement breaker for a Square D Homline
What is an Eaton CL?
The amount of receptacles required in a dwelling unit garage.
1 per vehicle bay
210.52(G)(1)
Is this installation NEC compliant?
No
240.81
What minimum size copper bond wire is needed for equipotential bonding of pool equipment?
#8 solid
680.26(B)
Which is an electrician's favorite band?
AC/DC
The alternative replacement breaker for a Challanger
What is an Eaton BR?
A receptacle must be located within ____ft of an air conditioner
25
210.63
The wire size and breaker size you would use for this AC unit.
#10 Copper
50A Breaker
440.4(B)
Flexible Metal Conduit can be used as the equipment grounding conductor if the circuit is _____Amps or less
20
250.118 Note other requirements that must also be met
Where do electricians get their supplies?
The Ohm Depot
The alternative replacement breaker for a Square D QO
What is an Eaton CHQ?
Bathroom lights cannot be installed with bathroom receptacles. True or False
False. If the parameters are met
210.11(C)(3) and Exception
What is the maximum distance
30
550.32(A)
Equipment Grounding Conductors can be taped green at the time of installation at every accessible point, IF ____AWG or larger
4
250.119(A)
Where was the electrician so excited to go shopping with his wife?
To the outlet mall.
The alternative replacement breaker for a Bryant
What is an Eaton BR?
When does a branch circuit extension NOT require AFCI protection?
if less than 6ft AND no devices are added.
210.12(D) Exception
The minimum distance needed above the tub
8ft
410.10(D)(1)
What system or material is not permitted for use as a Grounding electrode.
there are multiple answers
1. Metal underground gas piping systems
2. Aluminum
3. The structures and structural reinforcing steel described in 680.21(B)(1) and (B)(2)
250.50(B)