Natural Draft
t-couple
misc
100

Is an inducer found on a natural draft furnace?

no

100

Loaded thermocouple reading

10mv

100

If a furnace keeps tripping on limit, a common cause might be a

dirty filter

200

Why are natural draft furnaces no longer available? 

inefficient

200

Disconnected thermocouple reading

20-30 mv

200

electric/electric unit

electric heat/ electric cooling package unit

300

How many pressure switches on a natural draft furnace?

0

300

Flame sensor reading

0.5-4.5 microamps

300

You hear a spark but furnace does not light, check for... 

Cracked ceramic insulator

400

What kind of vent pipe is used for package units?

none

400

Does a thermopile light the burners?

no

400

What proves burner flame with an HSI?

flame sensor

500

A pressure switch proves what is working?

inducer

500

Besides an inducer, what else can be used to prove combustion airflow?

vane switch

500

A pilotless system uses...

HSI or Spark