Tanks, Vessels & Columns
Pumps
Compressors
Heat Exchangers
Fired Equipment
100

It keeps oxygen from mixing with liquids, and from oxidization.

Nitrogen

100

Pumps that move condensate from the overhead reflux drum as a reflux back to distillation column.

Reflux Pumps

100

A compressor that expands and compresses residue gas.

Turbo Expander-Compressor

100

What causes fouling in the heat exchangers?

Impurities in the cooling water

Scale 

Slime 

Corrosion

100

It is a heat resistant material that reflects heat and radiation from fuel gas burners back to the tubes.

Refractory

200

What is the overhead product of demethanizer column?

Methane or C1

200

Low lube oil pressure often is a result of__________.

High differential pressure of filters

Faulty PCV

Lube oil pump strainer clogged

200

Compresses ethane and propane and send both compressed gases to a condenser where it is used as refrigerant.

Refrigerant Compressor

200

In a Sulfur Cooler heat exchanger, what fluid is used to cool the hot sulfur in the shell-side?

Boiler Feed Water or BFW

200

Air registers allow air into furnace and at the same time control the _______of the flame in the firebox.

Shape

300

Uses a catalyst to convert H2S and SO2 into sulfur.

Catalytic Converter

300

Are large pumps that transfer product from one gas plant to another gas plant, NGL fractionation plant, or distribution facilities. 

Pipeline Pumps

300

It supplies combustion air to the reaction furnace and auxiliary furnace/burners.

Sulfur Recovery Air Blower

300

Gas chillers are used in series to chill and condense what?

Natural Gas

300

What do you call when the flame inside the firebox touches the coil tubes and forms a layer of coke. 

Flame Impingement

400

Tanks that separate unwanted hydrocarbons from recovered steam condensate.

Steam Condensate Skim Tanks

400

Corrective actions when a pump is observed to be having a high bearing temperature.

Check lube oil system

Check the cooling water system

Check the pump for any abnormal vibration or noise

Report to you supervising operator

400

The remaining fuel gas to be compressed in the regeneration gas compressor is also called as _______.

Residue Gas

400
It is used to cool depropanizer bottom products.

Air Coolers or Fin-Fan Coolers

400

Reheats the process gases before they go to the catalytic conversion reactor.

Auxiliary Furnace

500
A column that brings two feeds together to have a vapor-liquid contact.

Contactor Column

500

Methanol injection pumps inject methanol to prevent the formation of ___________ in the process piping.

Hydrates

500

You could adjust __________ if the turbine speed of the compressor is too high.

Governor

500
Give at least 1 symptoms of a fouling heat exchanger.

Abnormal changes to temperature

Abnormal changes to pressure

Abnormal changes to the flow of fluid

500

Located at the ground level that lights the pilot flame on top of the stack and ignites the pilot burner.

Flame Front Generator