Heating Controls
1
2
3
4
100

________ are often controlled by individual thermostats.

Electric radiant heating elements 


100

Baseboard heaters transfer heat by


convection

100

Ceiling-mounted radiant heating panels are typically constructed of 


gypsum board

100

A disadvantage of a central forced-air electric furnace is that


there is no zone control for individual rooms.

100

The material often used to manufacture electric strip heater element wire is


nickel chromium (nichrome).

200

An isolating thermostat subbase is easily identified because it has which of the following terminals?


RH and RC

200

The fusible link is best described as a(n) 


one-time safety device.

200

If the thermostat is calling for heat, but the appliance is providing insufficient heat, which of the following is the most likely cause for system malfunction?


The supply voltage to the appliance is too low.

200

On furnaces that are equipped with belt-driven blower assemblies, which of the following can result if the belt is too loose?


Reduced airflow and increased internal appliance temperature

200

Three common controls used in central electric heat applications are 


thermostats, contactors, and sequencers.

300

If a fusible link is found to be defective, which other system component must be replaced as well?


The limit control

300

The sequencer is responsible for 


staggering the starting and stopping of multiple stages of electric heat.

300

What is the approximate efficiency of an electric furnace with respect to its ability to convert electrical energy to heat energy?


100%

300

Electric baseboard heaters are typically controlled by


heater-mounted line-voltage thermostats.

300

If the proper voltage is supplied to an electric heating element and it does not get hot, 


the heating element is defective.

400

What is the purpose of an interlock circuit on an electric forced-air furnace?


It prevents the heaters from coming on if the blower is not energized.

400

The wiring diagram that shows the location of each system component is the 


pictorial diagram.

400

From an installation standpoint, electric boilers have the benefit of not requiring


flue or vent piping.

400

The electric resistance strip heaters in an electric furnace are insulated from the rest of the appliance using which materials?


Mica or ceramic

400

What is the difference between resistance heating and heat pump heating?

  • Resistance heating converts electricity directly into heat.
  • Heat pumps transfer heat from outside to inside using refrigeration and are more energy efficient.
500

The low-voltage thermostat is often used to control an electric heating system because it is compact, quick to respond to load changes, and it


is safe.

500

The heat anticipator is a(n)


adjustable device that is wired in series with the thermostat’s heating contacts.

500

Portable or small space heaters with glowing coils transfer heat by


radiation

500

Dirty air filters on an electric forced-air furnace can cause


reduced airflow and increased internal appliance temperature.

500

TWO PART QUESTION WORTH DOUBLE!

A)  What is the formula for calculating electrical power?

B) How many watts does a 240-volt heater draw if it uses 20 amps?

A) P = V × I (Power = Voltage × Current)

B) P = 240 × 20 = 4,800 watts