This document shall be known as the _____.
(A) Uniform Plumbing Code (C) National Plumbing Code
(B) Universal Plumbing Code (D) World Plumbing Code
A 101.1
Fixtures having concealed slip-joint connections shall be provided with _____.
(A) a utility space or access panel (C) red brass fittings
(B) a ladder and a light fixture (D) rubber gaskets
A 402.10
The code requirement for “an adequate supply of potable running water” is for _____.
(A) cleansing and sanitation (C) water-cooled equipment
(B) protection of trap seals (D) hydronic systems
A 601.2
Except for plastic pipe, in lieu of a water test, drainage piping may be tested with _____.
(A) air (C) smoke
(B) ether (D) gas
A 712.1
Each fixture trap shall have a liquid seal of _____.
(A) not less than 2 inches (C) both A and B
(B) not more than 4 inches (D) none of the above
C 1005.1
When the requirements within the jurisdiction of this plumbing code conflict with the requirements of the
mechanical code, _____ shall prevail.
(A) the Mechanical Code (C) the Building Code
(B) this code (D) either code
B 102.1
Trough urinals shall be _____.
(A) permissible if constructed of concrete (C) prohibited
(B) required in large associations (D) allowed in bus stations
C 405.2
Ballcocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening of the overflow pipe of not less than _____.
(A) 1/2 inch (C) 3 inches
(B) 1 inch (D) 6 inches
B 603.5.2 and
Table 603.2
The acceptable fitting for connecting a horizontal drain line with another horizontal drain line is a _____.
(A) sanitary tee (C) combination wye and 1/8 bend
(B) cross tee (D) side inlet 1/4 bend
C 706.3
One trap may serve a set of not more than _____ single compartment sinks.
(A) two (C) three
(B) one (D) four
C 1001.2
To obtain a permit, the applicant shall first file _____ therefore in writing on a form furnished by the Authority Having Jurisdiction for that purpose.
(A) a request (C) an application
(B) for permission (D) plans
C 104.3
The minimum distance from a side wall or partition to the center of a urinal shall be _____ inches.
(A) 6 (C) 18
(B) 12 (D) 24
B 402.5
After allowing for friction and other pressure losses, the residual water pressure shall be at least _____.
(A) .433 psi (C) 15 psi
(B) 7.5 psi (D) 29 psi
C 608.1
The maximum trap loading for a 3 inch trap is _____.
(A) one unit (C) four units
(B) three units (D) six units
D Table
702.2(1)
Floor drains shall connect into a trap so constructed that it can be _____.
(A) accessible (C) readily cleaned
(B) easily removed (D) none of the above
C 1006.1
This code is an ordinance to provide _____ for the protection of the public health, safety, and welfare.(A) guidelines
(B) maximum requirements and standards
(C) suggested ways of installation
(D) minimum requirements and standards
D 101.3
The water supply to a bathtub and whirlpool bathtub filler valve shall be protected by an _____ .
(A) air break (C) ASSE 1017
(B) air gap (D) ASSE 1070
B 409.5
The quantity of water required to be supplied to every plumbing fixture shall be represented by _____.
(A) gallons per minute (C) fixture units
(B) feet per second (D) available head pressure
C 610.3
A domestic dishwasher, with independent drain, has a drainage fixture unit value of _____.
(A) 2 (C) 4
(B) 3 (D) 1
A Table 702.1
Each building trap when installed shall be provided with _____.
(A) a cleanout
(B) a relieving vent or fresh air intake on the inlet side of the trap
(C) both A and B
(D) none of the above
C 1008.1
Temporary connection of the plumbing equipment to the source of energy or fuel for the purpose of testing_____. (A) is not allowed unless the inspector is present (B) shall be permitted to be authorized by the Authority Having Jurisdiction (C) is not allowed unless the equipment has been inspected and approved (D) is not allowed under any circumstances
B 105.4
The path of travel to an emergency eyewash shall be _____.
(A) clearly identified (C) no more than 50 feet
(B) in a straight line (D) no more than 100 feet
A 416.4
A type of plastic water piping that may be tested with air is _____.
(A) PVC (C) PE
(B) CPVC (D) PEX
D 609.4
Dual sewage ejectors for public use require _____ alarm.
(A) audio (C) visual
(B) audio and visual (D) audio or visual
B 710.9
The developed length of a 2” trap arm, from the trap weir to the inner edge of the vent shall not exceed
_____ feet.
(A) 3 (C) 6
(B) 5 (D) 10
B 1002.2 and
Table 1002.2