UPC Chapter 3
UPC Chapter 4
UPC Chapter 5
UPC Chapter 6
UPC Chapter 7
100

A drinking fountain installed outside shall be connected to an approved drainage system.

True

100

Screws or bolts for securing floor-mounted fixtures shall be _____.


brass

100

Plastic piping used for venting water heaters shall be _____.

approved

100

The code requirement for “an adequate supply of potable running water” is for _____.

cleansing and sanitation

100


The maximum fixture unit loading allowed on a 2 inch waste stack is _____.

16

200


PEX piping may be coupled together with shielded couplings.

False

200


Fixtures having concealed slip-joint connections shall be provided with _____.

a utility space or access panel

200


It shall be unlawful for any person to install, remove, or replace any water heater without
first _____.

obtaining a permit from the Authority Having Jurisdiction

200

The primary reason for installing backflow prevention assemblies is to _____.

prevent pollution or contamination of the potable water supply

200


Three-inch horizontal drainage piping shall have a grade or slope of not less than _____ inch per foot.

1/4

300

Section 312.2 prohibits the direct embedment of hubless cast-iron pipe in a concrete slab.

True

300

The overflow pipe from a fixture shall be connected on the _____.

house or inlet side of the fixture trap

300

Vent connectors of natural draft appliances _____ be connected to mechanical draft systems operating under positive pressure.

shall not

300


The minimum height of the atmospheric vacuum breaker above the highest part of a urinal equipped with a flushometer valve: _____ inch(es)


6

300

The maximum trap loading for a 3 inch trap is _____ unit(s).

6

400


It is permitted to drill and tap a vent pipe to connect an indirect waste pipe.

False

400


The diameter of a waste and overflow for a bathtub shall not be less than _____.

1 1/2 inches OD

400


A vent connector connected to a chimney flue serving a fireplace is _____.

prohibited unless the fireplace flue opening is permanently sealed

400


PEX tubing shall not be installed within the first _____ inches of piping connected to a water heater.

18

400


The minimum sizes of vertical and horizontal drainage shall be determined from the _____.

total fixture units

500


Disposal of sewage, or other liquid wastes, shall be by means of _____.

the drainage system of the building or premises

500

No dry or chemical closet (toilet) shall be installed in any building used for human habitation unless first approved by the _____.

health officer

500

The minimum capacity for storage water heater is _____.

based on the “first hour rating ” and the number of bedrooms and bathrooms

500


Each outlet on a nonpotable waterline that may be used for drinking purposes shall be posted _____.

CAUTION - NONPOTABLE WATER DO NOT DRINK

500

The minimum size trap and trap arm for a bathtub is _____ inches

1 1/2