A person should move this many feet away to avoid step potential.
What is 10 meters or 33 feet?
This dirt structure increases the cover over utility lines.
What is a blister or berm?
In 2016, utility strikes cost this amount in property damage.
What is 1.7 billion dollars?
At proposed crossing locations, Hydro-Vac must be used at what intervals.
What is 10 feet?
Overhead signs shall include stickers with this minimum letter height.
What is 3 inches?
Gas and oil utility lines are marked by this color.
What is Yellow?
How many days ahead does a One-Call need to be made?
2-3 business days
This piece of equipment is responsible for the most utility strikes.
What is a backhoe?
This many feet of overhead utility clearance is required above moving equipment if the voltage is under 50,000
What is 4 feet?
What two things are not allowed within 24" of a daylighted cable when excavating?
Hand-held power tools or mechanical excavators
On a wind site, the use of any hand-held power tool or excavator is prohibited within this many feet of an underground utility locate.
What is 2?
The Uniform Color Code green marks these utilities.
This is the #1 cause of utility strikes.
What is failure to locate?
This call must be made before any subsurface penetration or sign installation can be done.
What is a "One-Call"?
Overhead power line signage is required to have this many flags attached to them.
What is 2?
What is 25 kV?
DAILY DOUBLE: This appendix has pipeline crossing information.
What is E?
If a piece of equipment strikes an overhead powerline, barricades should be placed at this interval.
Metal t-posts need to be installed in areas where this potential hazard is present.
What is livestock?
This color is used to mark storm and sewer drains.
What is green?
In the event of an underground utility strike, this person is responsible for securing the scene.
Who is the Foreperson?
This appendix must be used in the event of an underground or above ground utility strike.
What is G?
This appendix is where you go for equipment dimensions and weight spec tables.
What is D?
Hydro Excavation water pressure can reach this many PSI.
What is 1,700?
Guard structures are required at all solar overhead line crossings that are up to what height?
What is 50 feet?