Building Construction
Fire Extinguishers
Fire Behavior
Fire Hose
Department Policy
200

Which type of building construction provides the highest level of protection from fire and structural collapse?

Type I-Fire Resistive

200

What types of materials do Class B fires involve?

Combustible liquids and gases

200

What are the 3 parts of the fire triangle?

Fuel, Heat, Oxygen

200

Which type of hose transports water from the hydrant or static water source to the pumping apparatus?

Supply hose

200

Backing up fire apparatus

OG 505-__________MUST be used at all times

Spotters

400

Type IV buildings are constructed of:

Heavy Timber

400
Class C fires involve:

energized electrical equipment

400

This fire behavior event occurs when unburned gases ignite rapidly after a ventilation opening is made.


What is backdraft

400

Which hose roll leaves only one coupling exposed?

Straight Roll

400

OG 407-The Firefighter will call the training officer before_______ indicating the reason they will not be attending training.

18:00hrs

600

Which type of building construction may have interior walls and beams constructed of wood, but requires that exterior walls be made of noncombustible materials?

Type III

600

What is the PASS method stand for?

Pull the pin, Aim the hose/nozzle, Squeeze the nozzle, Sweep at the base of the fire.

600

This dangerous condition occurs when fire rapidly transitions from the growth stage to full-room involvement.


What is flashover

600

Which is the best way to load large diameter supply hose?

Flat Load

600

OG 1401-Rural structural fire and alarms apparatus response is:

Pumper 32, Tanker 36, Pumper 34, Tanker 35, Rescue 33

800

How is the distance known as the collapse zone measured?

1.5x the building height.

800

Class D fire involve:

Combustible metals


800

This stage of fire occurs when fuel is first ignited and heat begins to build.

What is the incipient stage?

800

What type of hose lays are used for our pre-reconnects?

Minute Man


800

OP 1707-All members of the GVDFD must reside:

 within our coverage area.

1000

Basement fires are likely to become more hazardous than other compartment fire due to:

Limited Ventilation

1000

Class A fires involve:

Ordinary combustibles (Wood, Paper)

1000

This term describes the minimum temperature at which a fuel produces enough vapors to ignite.



What is the ignition temperature?

1000

What is a higbee indicator?

Notches or grooves cut into coupling lugs to identify by touch or sight the exact location of the higbee cut. 

1000

OP 204-No fire department personnel shall respond to the fire hall at any time if:

their ability is impaired by an intoxicating beverage or drug.