100

When receiving a package and performing the wipe test, how many sq cm should be wiped?

300 cm2

100

The Radiation Safety Committee at WMC meets at what frequency?  

Quarterly

100

What therapeutic Nuclear Medicine procedures are performed at WMC?

Ra-223 Xofigo and Y-90 Sirspheres

100

True or False.  It is okay to store your personal belongings in the hot lab if you are the only one working in the department.   

False.  It is never okay to store personal belongings, food, or drink in the hot lab.  

100

What items should be checked and recorded on a GM counter every day prior to use?  

Battery, source reading, and background

200

When receiving deliveries from the pharmacy, they should be surveyed at what distance(s)?

The surface and 1 meter

200

What activity is considered to be a MAJOR spill for Tc99m?  


100 mCi 


200

What special paperwork is required of any therapeutic Nuclear Medicine procedure?  

Written Directive

200

It is acceptable for the Pharmacies to have the code to our Hot Labs in order to let themselves in when we aren't here. True or False

False.  Security ALWAYS has to let them into the Hot Labs when we are not in the building(s).  

200

Area surveys should be performed at which times?

A.  Daily  

B.  Only when contamination is suspected  

C.  Surveys are not necessary as long as you are careful  

D.  Both A & B


300

What is the maximum permissible limit of removable surface contamination allowed on a package?

2,200 dpm/100 sq sm 

(300 sq cm=6,600 dpm)

300

What activity is considered to be a MAJOR spill for FDG?


10 mCi 


300

The patient's identity must be verified before the administration of a therapeutic dose.  Which methods of identification are acceptable?

Full name (stated by the patient and matching it with chart), drivers license, DOB, SSN, address, patient wrist band

300

What type of posting is required on the door of the hot lab or anywhere that radioactive materials are used or stored?

Caution: Radioactive Materials

300

Actual dose and prescribed dose may not differ by more than _____%. (State Reg)

20% is the State Reg, but we follow a 10% rule 

400

What label would be required on a package with the following measured exposure rates?  

Surface=5 mR/hr and 1 meter=0.5 mR/hr

Yellow II

400

One of our main goals is to achieve low occupational exposures and exposures to the public that are also as low as possible.  What is this program called and how do we achieve it?


ALARA (As Low as Reasonably Achievable) is achieved by Time, Distance, and Shielding.



400

Who must sign the Written Directive?

The technologist, a dose verifier, and the authorized user

400

What type of posting is required where a major portion of the body may receive in excess of 5 mR/hr or 100 mR in 5 consecutive days.

Caution: Radiation Area

400

The annual occupational total dose limit is _____ rems.

5 rems

500

What UN number should appear on the outside of a package containing limited quantity of RAM?  

UN2910 Limited Quantity.  UN2908 is Empty.  *Don't flip placards and place outside of delivery boxes, put them inside of the box.  We aren't shipping radioactive materials back. 

500

What is the occupational dose limit to an embryo/fetus for the duration of a pregnancy?

0.5 rem

500

What four improper technologist actions constitute a misadministration?

Wrong radiopharmaceutical

Wrong route of administration

Wrong patient

Wrong activity (differs by more than 20%)



500

What type of posting would be required in an area where a major portion of the body may receive a dose in excess of 100 mR/hr?

High Radiation Area

500

True or False.  All radioactive materials should be properly secured when not under the constant surveillance and immediate control of an authorized user, RSO, or nuclear medicine technologist.  

TRUE, TRUE, TRUE!  We really should not be leaving doses anywhere that cannot be directly seen by one of us.  i.e., the stress rooms.