Code Book
Wiring 101
True or False
What went wrong?
Calculations
100

Every ___ the National Electrical Code is revised.

What is every three years ?

100

The first step in planning a wiring project.

What is determining the load, as this influences all other decisions ?

100

An arc flash can produce temperatures of 35,000°F.

What is True ?

100

Susan insisted, "Ground wires are just decorative!" Now her metal lamp gives a friendly tingle when touched.

What is not grounding the metal lamp ?

100

The voltage values used throughout the text book for all calculations.

What is 120v and 240 v ?

200

NEC Table 220.14(J) states that the minimum load requirement for dwelling units is...

What is 3 volt-amperes per square foot ?

200

The required size of conductor for a 20-amp branch circuit. 

What is #12 AWG ?

200

Aluminum wiring was commonly used in homes during the mid-1960s to early 1970s.

What is True ?

200

Dad thought one 15A circuit could handle the basement fridge, freezer, and space heater. The breaker trips every winter.

What is exceeding circuit ampacity per NEC 210.23 ?

200

You need to run five (5) 12 AWG THHN copper wires in EMT conduit. The minimum size EMT conduit required is...

What is 1/2 EMT conduit ?

- 0.0133 in2 per conductor 

- 5 wires × 0.0133 in2 = 0.0665 in2

300

According to NEC 210.52(A)(1), the maximum distance that a receptacle outlet can be located from any point along a wall space in a dwelling unit is.... 

 What is 6 ft? 

300

GFCI outlets trip when they detect a current imbalance of this many milliamps.

What is 5 milliamps ? 
300

Galvanic action occurs when two similar metals are in contact under dry conditions.

What is False ?

300

Handy Hank installed a standard outlet in his garage 18" off the floor. The inspector failed it for missing this feature.

What is GFCI protection per NEC 210.8(A)(2) ?

300

This size of copper conductor is required for a 50A, 240V circuit.

What is 6 AWG ? 

- NEC Table 310.16

400

The minimum clearance required for LED drivers according to the NEC.

What is 3 inches ?
400

This device is required to protect 120V circuits from overcurrent and must match the wire gauge.

What is a circuit breaker ?

400

Gray insulation on a conductor can be used as an ungrounded "hot" conductor.

What is False ? 

400

For his backyard shed, Carl used 135 feet of #12 wire on a 20A circuit. The LED lights glow like candlelight.

What is ignoring voltage drop per NEC 210.19(A) ?

400

The maximum number of 120V, 15A lighting circuits needed for a 2,400 sq. ft. dwelling. 

What is 4 circuits ? 

- 2,400 sq. ft. × 3 VA/sq. ft. = 7,200 VA

- 7,200 VA / 120V = 60A

- 60A / 15A = 4 circuits

500

The definition of a bathroom according to the NEC. 

What is an area with a sink and one or more fixtures such as a toilet, shower, or tub ?

500

This material is unsuitable for push-in terminal connections.

What is stranded conductors ?

500

GFCI receptacles are designed to trip when the current imbalance reaches or exceeds 3-8 milliamperes.

What is False ?

500

Greg installed a 30A dryer outlet using 14 AWG wire "because it was cheaper." The melting smell started after 10 minutes.

What is undersized conductors for circuit ampacity per NEC 310.15 ?

500

Calculate the box fill for a switch box with four 12 AWG Romex, two clamps, and a dimmer.

What is 27 in3 // 4 11/16 x 1 1/2

- 8 conductors x 2.25 = 18 in3

- 4 grounds ( 1 x 2.25 ) = 2.25 in3

- 2 clamps ( 1 x 2.25 ) = 2.25 in3

- dimmer ( 2x 2.25 ) = 4.5 in3