Surgical Instruments
Instrument Transportation
Mechanical Washers
Random
Decontamination
100

Microorganisms found in blood, tissue, and or body fluids on surgical instruments is referred to as

a. An infection
b. Bioburden
C. contaminants

b. Bioburden

100

Which of the following would be acceptable to transport used operating room surgical instrument trays?

a. Open wire cart
b. Supply delivery cart
c. Closed case cart

C. Closed case cart

100

The solution is considered Neutral when the pH is 


b. 7

100

The weakest part of a hemostat

box lock

100

The removal of contamination from an item to the extent necessary for further processing for its intended use, According to AAMI.

a. Cleaning
b. sterilization
c. disinfection

A. CLeaning

200

Before a medical device is cleaned, what information must the technician have before processing it?

a. Directions from the department that purchased it
b. Manufacturess' instruction for use
c. Sales representative instruction for operation

b. Manufactures instruction for use

200

When manually cleaning surgical instruments, the final rinse in the cleaning process should be 

a. critical or treated water
b. tap water
c. saline

b. critical or treated water

200

Enzyme-based detergents contain organic substances that assist in the breakdown of 

a. Hard water
b. Disinfectants
c. Protein, soils and blood

c. Protein, soils, and blood

200

After manually cleaning a surgical instrument, it is acceptable to treat the instrument with a disinfectant wipe

a. Yes
b. only if stated in instrument manufacture instruction for use (IFU)

c. if the instrument was heavily soiled

b. only if stated in the instrument manufacturers instruction for use (IFU)

200

The use of physical or chemical means to remove, interact, or destroy bloodborne pathogens on the surface of an item is known as

a. Cleaning
b. disinfection
c. Decontamination

C. Decontamination

300

Generally, fiber optic light cables should be cleaned

a. in an ultrasonic cleaner
b. with a soft brush and mild detergent
c. in an Automated endoscope reprocessor

b. soft brush and mild detergent

300

If used instruments in a basin are not clearly visible, which of the following should be use to pick them up?

a. Forceps
b. barehand
c. gloved hands

a. Forceps

300

Chemical disinfectants are frequently misused because

a. the department policy and procedure are outdated
b. the current instruction for use were not followed
c. there is insufficient time for the process

b. the current instruction for use were not followed

300

Which of the following medical device would require only low-level disinfection

a. blood pressure cuff
b. hemostat
c. flexible endoscope

a. blood pressure cuff

300

Which of the following terms refers to disease-producing microorganisms?

a. Biofilm
b. Pyrogen
c. Pathogen

c. Pathogen

400

According to Spaulding's classification of medical devices, semicritical items requires

a. low-level disinfection
b. High-level disinfection
c. sterilization

b. High level disinfection

400

Surgery Instrument Carts transported throughout the hospital should be

Enclosed

400

A cleaning solution having a pH of 9 is said to be?

Alkaline

400

Iodine is used primarily to reduce microograinms on which of the following

a. workstation
b. patient care equipment
c. skin

skin

400

Negative pressure refers to

a. recirculating air within the room
b. air exhausted directly to the outside
c. Circulation of air in a confined space

b. Air exhausted directly to the outside

500

Wrap a mayo tray square fold


500

Explain DOFFING

Shoe covers
gloves
gown
face shield
mask
headcover
wash hands

500


TOSI test 

Used the check the efficiency of the Washers

500

A Richardson Retractors

A hand held retractor

Used for retracting

500

The spray force action of pressurized water against instruments being processed to physically remove bioburden