Masimo SET has over _____________ clinical studies.
100
Masimo SET® (Signal Extraction Technology) has the ability to read through ____________ and ____ _____.
motion
low perfusion
This system allows clinicians to monitor up to 500 patients from a central station and sends alarms to mobile devices.
Masimo Patient SafetyNet™
PSN
This noninvasive measurement offered by some Masimo devices helps guide blood transfusion decisions.
SpHb® (Total Hemoglobin)
Capnography measures this gas in exhaled breath to assess ventilation.
carbon dioxide (CO₂)
This technology helps clinicians prevent Hospital-acquired pressure injuries (HAPIs) , which are considered “never events” .
Centroid
Masimo ________ technologies read multiple wavelengths of light.
rainbow
This Masimo mobile app works with Patient SafetyNet to deliver alarm notifications to clinicians.
Masimo Replica®
This device:
•Insight into patient’s response to anesthetic drug and help avoid over sedation.
•Identifies bursts suppression
•Displays EEG on both sides of the brain with the DSA.
SedLine® Brain Function Monitoring
This portable Masimo device provides real-time monitoring of carbon dioxide (CO₂) in exhaled breath.
EMMA
_____
Acts as a central hub for monitoring and displaying multiple parameters:
Root
This Masimo device can measure carbon monoxide levels in emergency situations.
Rad-57
This Masimo device acts as a connectivity hub, integrating up to six medical devices at the bedside
iSirona™
_______ provides beat-to-beat cardiac output and other hemodynamic parameters using an existing arterial line.
LiDCO
This device is:
RRa® (Rainbow Acoustic Respiration Rate)
In a study during challenging conditions of motion and low perfusion, competitor pulse oximetry technology demonstrated ___% missed true alarms and ___% false alarms while Masimo SET® demonstrated __% and __%, respectively.
Nellcor Masimo
43% missed true alarms 5%
28 % false alarms 3%
Shah N et al. J Clin Anesth. 2012 Aug;24(5):385-91.
Masimo SET has the ability to read through motion and low perfusion because it can ________________.
Filter out the venous noise (artifact) caused by blood movement in the veins to read the true arterial signal.
_____
Acts as a central hub/monitor for monitoring and displaying multiple parameters:
Root
The Medtronic competitor to SedLine is called ________.
BISTM
This portable Masimo device provides real-time monitoring of carbon dioxide (CO₂) in exhaled breath. It also connects via Bluetooth.
Radius PCG
_____is a specialized SpO₂ (pulse oximetry) sensor designed specifically for cyanotic infants and children with congenital heart disease. These patients often have chronically low oxygen saturation, and standard sensors may not measure accurately at those low levels. It can read down to 60%.
Blue sensor
This device provides a tetherless option that allows patients to ambulate while still reading their pulse oximetry via bluetooth.
Radius PPG
________ automatically sends patient data from Masimo and third‑party medical devices directly to the EMR (Electronic Medical Record).
Iris Gateway
is like a universal translator hospital devices. It gathers data from monitors, pumps, and other equipment, converts it into a standard format, and delivers it directly into the patient’s electronic chart.
This handheld device can read SpHb, total hemoglobin.
Rad-67
______
is a family of capnography sampling lines that works in both sedated and non-sedated patients.
removes water vapor from the gas sample preventing condensation and ensuring accurate CO₂ readings.
Works in OEM devices
NomoLine
NomoLine-O